STARTER PIPE INSTALLATION
UNPACKING THE TWENTY6 SLIM-LINE BUILT-IN
FIREPLACE
The fireplace is shipped on a pallet. The venting
components are in one carton. Start with the carton that
contains the vent starter pipe, vent heat shields and air
and exhaust restrictors.
1. Before beginning, locate the TWENTY6 Slim-Line
Built-In Vent Adapter kit.
2. Using a 5/16” nut driver, remove the 8x #10 sheet metal
screws from the outer can vent access panel.
3. Using a 5/16” nut driver, remove the 6x #10 sheet metal
screws from the firebox heat shield access panel.
4. At this point, it is necessary to determine whether your
installation will require the addition of flow restrictors
for the combustion air inlet system, the exhaust
outlet, or both. Refer to the applicable vent chart
for your gas type and vent configuration on pages
20 & 21, if an air restrictor is required for your vent
configuration, prepare the air restrictor now. Identify on
the appropriate vent chart the number of tabs to open
on the air restrictor and do so now by breaking and
discarding these tabs.
5. Place the vent starter gasket on the back of the firebox,
it may be helpful to apply 3 or 4 very small dabs of high
temperature (500F) silicone (RTV) to hold the gasket in
place while continuing with the installation.
Box Contents
Restrictors
Outer
Heat Shield
Inner
Heat Shield
Starter
Pipe
Gasket