background image

= 239 mm (9.4 in)

f

min

 = - 3,1 kN/m² (- 64 psf)

= 419 mm (16.5 in)

f

max

 = + 5,4 kN/m² (+ 113 psf)

Fig. A

a

a

b

b

SolarWorld aG

Martin-Luther-King-Str. 24
53175 Bonn
Germany
Phone: +49 228 55920 0
Fax:   +49 228 55920 99
[email protected]
www.solarworld.de

SolarWorld france SaS

Hotel del`Entreprise 31, rue 
Gustave Eiffel 3800 Grenoble
France
Phone: +33 (4) 38 210050
Fax:   +33 (4) 38 210059
[email protected]
www.solarworld.fr

SolarWorld americas LLC.

25300 NW Evergreen Road 
Hillsboro, OR 97124
USA
Phone: +1-503-844-3400
Fax:   +1 805 388 6395
[email protected]
www.solarworld-usa.com

SolarWorld asia Pacific Pte. Ltd.

72 Bendemeer Road
# 07-01 Hiap Huat Housem
339941 Singapore
Singapore
Phone: +65 6842 3886
Fax:   +65 6842 3887
[email protected]
www.solarworld.sg

SolarWorld africa Pty. Ltd.

24th Floor
1 Thibault Square
Cape Town, 8001
South Africa
Phone: +27 21 421 8001
Fax:   +27 21 421 8002
[email protected]
www.solarworld-africa.co

www.solarworld.com

*tolerance: +/- 10mm (+/- 0.4 in)

= 239 mm (9.4 in)

f

min

 = - 3,1 kN/m² (- 64 psf)

= 419 mm (16.5 in)

f

max

 = + 3,1 kN/m² (+ 64 psf)

Fig. B

a

a

b

b

Fig. C

a

 = 223 mm (8.8 in)*

f

min

 = - 3,4 kN/m² (- 76 psf)

b

 = 837,5 mm (33.0 in)*

f

max

 = + 8,1 kN/m² (+ 170 psf)

a

a

b

Fig. D

a

 = 510 mm (20.1 in)*

f

min

 = - 2,4 kN/m² (- 50 psf)

b

 = 223 mm (8.8 in)*

f

max

 = + 5,4 kN/m² (+ 113 psf)

a

b

Fig. E

a

 = 239 mm (9.4 in)

f

min

 = - 1,44 kN/m² (- 30 psf)

b

 = 250 mm (9.8 in)

f

max

 = + 1,44 kN/m² (+ 30 psf)

a

b

F

F

F

F

F

Содержание Sunmodule Plus

Страница 1: ...caciones para el usuario Informazioni per l utente Informations pour l utilisateur www solarworld com Sunmodule Plus SW xxx poly Sunmodule Plus SW xxx mono black Sunmodule Protect SW xxx poly Sunmodul...

Страница 2: ...gen des Gesamtsystems entspricht Durch andere Anlagenkomponenten d rfen keine sch digenden mechani schen oder elektrischen Einfl sse auf das Modul ausge bt werden Module k nnen sich bei hohen Belastun...

Страница 3: ...ce Mounting The modules must be securely fixed at a minimum of 4 locations on the substruc ture Fixing is only allowed in designated areas In regards to Top Down mounting methods the maximum clamping...

Страница 4: ...de montaje Si est n conectados en serie los m dulos s lo pueden combinarse cuando tienen la misma intensidad el ctrica y conectados en paralelo solo se pueden combi nar si tienen la misma tensi n Los...

Страница 5: ...ere sottoposti ad una tensione superiore a quella autorizzata per il sistema L apertura posta all interno dell angolo del la cornice serve per lo scarico dell acqua e perci non deve essere chiusa Si c...

Страница 6: ...ts de l installation ne devraient produire aucun effet nocif m ca nique ou lectrique sur le panneau Les panneaux peuvent se courber si les contrain tes sont lev es C est pourquoi proximit de la face a...

Страница 7: ...SolarWorld Asia Pacific Pte Ltd 72 Bendemeer Road 07 01 Hiap Huat Housem 339941 Singapore Singapore Phone 65 6842 3886 Fax 65 6842 3887 service solarworld sg www solarworld sg SolarWorld Africa Pty Lt...

Отзывы: