![SolarPower SP4002 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/solarpower/sp4002/sp4002_installation-and-owners-manual_1314028005.webp)
W W W . S O L A R P O W E R . N E T . A U
Page 5 of 20
Revision: 9h Issued: 01 August 2008
Revision: 9h Issued: 01 August 2008
17)
Connect the Solar Hot Pipe and Solar Cold Pipe to the heater and
to the panels.
NOTE: ensure that the water inlet from the system pump flow is to
the lower left edge of the array, and that the water exits the
panels diagonally opposite and through the sensor outlet
fitting, and returns to the solar return on the tank.
18)
Upon completion of the water heater installation, check the panels
and associated plumbing for leaks while the pump is operating.
Leaks above the water line of the tank will suck air in, rather than
leak water out. When checking for leaks, if you can hear air
bubbling in the tank after the pump has been running for a while
(more than 5mins), it is likely that air is leaking in somewhere in
the piping.
COLLECTOR INSTALLATION IN CYCLONE AREAS
The
SolarPower SP4002
is
SUITABLE
for installation in cyclonic locations when installed
with an additional rail mounting and brackets to provide the required additional fixing to the roof
frame. This ensures conformance with AS1170.2. Three mounting rails meet the requirement for a C3
rated area.