Positive metal connector
Negative metal connector
Fig. 16: Connecting the DC cable to the connector
2. Insert the terminals in the corresponding plastic enclosures and lock them
in position by pushing them until the metal tabs are engaged with a “click”.
Fig. 17: Connecting the assembled connector to the corresponding plastic enclosures
3. Lock the cable glands with an appropriate torque (see figure below).
Fig. 18: Locking the cable glands
4. Check with a voltmeter of proper scale that the polarities and the DC
voltage values are correct.
RANGE
MAXMI N
REL
Hz %
P
C
800 00
Fig. 19: Checking DC voltage values with a voltmeter
5. Insert the connectors into the respective counterparts located at the
bottom of the inverter and push them until they are locked by a “click” of
the plastic side tabs.