INSTALLATION

The fixture is designed for indoor use only and must be used in a dry location with adequate 

ventilation. Ensure that none of the fixture’s ventilation slots are blocked and ensure that the 

fixture is fastened to a secure structure or surface. Do not use the fixture to illuminate sur

-

faces less than 8 m (approx 26ft.) from the fixture.

FASTENING THE FIXTURE TO A FLAT SURFACE

The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure 

that the surface and all fasteners used can support at least 10 times the weight of all fixtures 

and equipment they will support. Fasten the fixture Securely. Do not place it on a surface or 

leave it where it can be moved or fall over. 

If you install the fixture in a location where it may cause injury or damage if it falls, secure it 

as directed below with a securely anchored safety cable that will hold the fixture if the pri

-

mary fastening method fails.

MOUNTING THE FIXTURE ON A TRUSS

The fixture can be clamped to a truss or similar rigging structure in any orientation. When 

installing the fixture hanging vertically down, you can use an open-type clamp such as a 

G-clamp. When installing in any other orientation, you must use a half-coupler clamp

that completely encircles the truss or pipe circumference. 

To clamp the fixture to a truss:

1. Check that the rigging structure can support at least 10 times                                                             

the weight of all fixtures and equipment  to be installed on it.

2. Block access under the work area.

3. Working from a stable platform, hang the fixture on the

 truss and  fasten the rigging clamps onto the truss.

4. Secure the fixture with a safety cable as directed below.

5. Check that the head will not collide with other fixtures or objects.

WARNING! READ SAFETY INFORMATION ON    

PAGE 3 BEFORE INSTALLING THE FIXTURE.

Содержание HITMAN 230

Страница 1: ...USER MANUAL...

Страница 2: ...MP LIFE SPAN 5 INSTALLATION 6 7 AC POWER 7 FIXTURE OVERVIEW 8 DMX DATA LINK 9 CONNECTING AND USING DMX DATA LINK 9 FIXTURE OPERATION 10 11 TOKENS 12 FIXTURE MENU STRUCTURE CHART 13 DMX MODES CHARTS 14...

Страница 3: ...ERSONAL SAFETY Avoid direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded cir...

Страница 4: ...enses LED lights or cables Have the damaged parts replaced by an authorized technician at once Do not cover the ventilation slots when operating to avoid internal overheating Do not aim this product t...

Страница 5: ...he fixture 2 Unpack and ensure that there is no transportation damage before using the fixture Never attempt to operate a damaged fixture 3 If the fixture is not going to be hard wired to a mains supp...

Страница 6: ...mage if it falls secure it as directed below with a securely anchored safety cable that will hold the fixture if the pri mary fastening method fails MOUNTING THE FIXTURE ON A TRUSS The fixture can be...

Страница 7: ...on the power cable If you replace power plug on the power cable install a grounding type earthed plug with integral cable grip that is rated minimum 250 V 5 A The fixture has an auto ranging power sup...

Страница 8: ...g the fixture DMX personality Beam Angle Weight and Power Supply 2 Jog Scrolling Wheel and button 3 Digital Screen for viewing the menu 1 2 3 FIXTURE OVERVIEW 4 DMX IN DMX OUT 5 PowerCon Power In Conn...

Страница 9: ...rol of a fixture is required it must have its own DMX channels Fixtures that are required to behave identically can share the same DMX address and channels To add more fixtures or groups of fixtures w...

Страница 10: ...un mode and return to DMX control mode Select Exit and press once on the jog wheel to return to main menu SOUND TO LIGHT MODE by selecting Run Test Interface option in the menu you can turn on Sound R...

Страница 11: ...ameter of the fixture can be manually adjusted using the adjust interface Gobo Color Focus Prism Pan Tilt can be manually adjusted by changing the value 000 default to a value between 1 255 Select Exi...

Страница 12: ...ing Solaris fixtures The TOKENS are located above the digital screen on the back panel of the fixture This token indicates the maximum amount of power consumption Displays in Watts This token indicate...

Страница 13: ...000 512 Adjust Focus Default value 001 000 512 Adjust Prism Default value 000 000 512 Adjust X Default value 000 000 512 Adjust Y Default value 000 000 512 Adjust Exit Run Test Auto Run OFF ON Auto r...

Страница 14: ...T GREEN LAVENDER LAVENDER LAVENDER PINK PINK PINK YELLOW YELLOW YELLOW MAGENTA MAGENTA MAGENTA CYAN CYAN CYAN CTO 260 CTO 260 CTO260 CTO 190 CTO 190 CTO 190 CTB 8000 CTB8000 CTB8000 BLUE BLUE BLUE WHI...

Страница 15: ...2 shake fast speed Gobo3 shake slow speed Gobo3 shake fast speed Gobo4 shake slow speed Gobo4 shake fast speed Gobo5 shake slow speed Gobo5 shake fast speed Gobo6 shake slow speed Gobo6 shake fast spe...

Страница 16: ...10 PAN 0 255 Pan movement range 540 Degrees 11 PAN FINE 0 255 12 TILT 0 255 Tilt movement range 270 Degrees 13 TILT FINE 0 255 14 FUNCTION 0 11 12 24 25 37 38 50 51 62 63 255 Unused range Fast defaul...

Страница 17: ...outdoor events for example If one or more of these factors is present inspect fixtures within their first 100 hours of oper ation to see whether cleaning is necessary Check again at frequent intervals...

Страница 18: ...fects instant open and black out Dimmer 0 100 Linear Dimmer Dynamic Effect Color Wheel 14 colors plus open rotation with variable direction and speed Static Gobo Wheel 17 gobos plus open wheel rotatio...

Страница 19: ...Power Supply Auto Ranging Electronic Switch Mode INCLUDED ITEMS 3 ft Power Con Power Cable User Manual Specifications are subject to change without notice For latest product specifications see www Glo...

Страница 20: ...LOSS OCCASIONED BY THE USE OF INABILITY TO USE OR RELIANCE ON THE INFORMATION CONTAINED IN THIS MANUAL THE GLOW LOGO THE SOLARIS LOGO THE GLOW PROFESSIONAL NAME THE SOLARIS PROFESSIONAL NAME AND ALL O...

Отзывы: