Disconnect the fixture from mains power and allow to cool completely before cleaning or 

servicing. Service fixtures in an area where there is no risk of injury from failing parts, tools 

or other materials. Excessive dust, smoke fluid, and particle buildup degrades performance, 

causes overheating and will damage the fixture. Damage caused by inadequate cleaning or 

maintenance is not covered by the product warranty.

CLEANING

The cleaning of lenses must be carried out periodically to optimize light output. Cleaning 

schedules for lighting fixtures vary greatly depending on the operating environment. It is 

therefore impossible to specify precise cleaning intervals for the fixture. Environmental fac

-

tors that may result in a need for frequent cleaning include:

• Use of smoke or fog machines.

• High airflow rates (near air conditioning vents, for example).

• Presence of cigarette smoke.

• Airborne dust (from stage effects, building structures and fittings or the natural environ

-

ment at outdoor events, for example).

If one or more of these factors is present, inspect fixtures within their first 100 hours of oper

-

ation to see whether cleaning is necessary. Check again at frequent intervals. This procedure 

will allow you to assess cleaning requirements in your particular situation.

Use gentle pressure only when cleaning, and work in a clean, well-lit area. Do not use any 

product that contains solvents or abrasives, as these can cause surface damage.

CLEANING THE FIXTURE

1. Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. Vacuum or gently blow away dust and loose particles from the outside of the fixture and 

air with low-pressure compressed air

3. Clean lenses by wiping gently with a soft, clean lint-free cloth moistened with a weak de

-

tergent solution. Do not rub the surface hard: lift particles off with a soft repeated press. Dry 

with a soft, clean, lint-free cloth or low pressure compressed

air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass 

cleaner or distilled water.

4. Check that the fixture is dry before reapplying power.

MAINTENANCE

WARNING! READ SAFETY INFORMATION ON    

PAGE 3 BEFORE SERVICING THE FIXTURE.

Содержание HITMAN 230

Страница 1: ...USER MANUAL...

Страница 2: ...MP LIFE SPAN 5 INSTALLATION 6 7 AC POWER 7 FIXTURE OVERVIEW 8 DMX DATA LINK 9 CONNECTING AND USING DMX DATA LINK 9 FIXTURE OPERATION 10 11 TOKENS 12 FIXTURE MENU STRUCTURE CHART 13 DMX MODES CHARTS 14...

Страница 3: ...ERSONAL SAFETY Avoid direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded cir...

Страница 4: ...enses LED lights or cables Have the damaged parts replaced by an authorized technician at once Do not cover the ventilation slots when operating to avoid internal overheating Do not aim this product t...

Страница 5: ...he fixture 2 Unpack and ensure that there is no transportation damage before using the fixture Never attempt to operate a damaged fixture 3 If the fixture is not going to be hard wired to a mains supp...

Страница 6: ...mage if it falls secure it as directed below with a securely anchored safety cable that will hold the fixture if the pri mary fastening method fails MOUNTING THE FIXTURE ON A TRUSS The fixture can be...

Страница 7: ...on the power cable If you replace power plug on the power cable install a grounding type earthed plug with integral cable grip that is rated minimum 250 V 5 A The fixture has an auto ranging power sup...

Страница 8: ...g the fixture DMX personality Beam Angle Weight and Power Supply 2 Jog Scrolling Wheel and button 3 Digital Screen for viewing the menu 1 2 3 FIXTURE OVERVIEW 4 DMX IN DMX OUT 5 PowerCon Power In Conn...

Страница 9: ...rol of a fixture is required it must have its own DMX channels Fixtures that are required to behave identically can share the same DMX address and channels To add more fixtures or groups of fixtures w...

Страница 10: ...un mode and return to DMX control mode Select Exit and press once on the jog wheel to return to main menu SOUND TO LIGHT MODE by selecting Run Test Interface option in the menu you can turn on Sound R...

Страница 11: ...ameter of the fixture can be manually adjusted using the adjust interface Gobo Color Focus Prism Pan Tilt can be manually adjusted by changing the value 000 default to a value between 1 255 Select Exi...

Страница 12: ...ing Solaris fixtures The TOKENS are located above the digital screen on the back panel of the fixture This token indicates the maximum amount of power consumption Displays in Watts This token indicate...

Страница 13: ...000 512 Adjust Focus Default value 001 000 512 Adjust Prism Default value 000 000 512 Adjust X Default value 000 000 512 Adjust Y Default value 000 000 512 Adjust Exit Run Test Auto Run OFF ON Auto r...

Страница 14: ...T GREEN LAVENDER LAVENDER LAVENDER PINK PINK PINK YELLOW YELLOW YELLOW MAGENTA MAGENTA MAGENTA CYAN CYAN CYAN CTO 260 CTO 260 CTO260 CTO 190 CTO 190 CTO 190 CTB 8000 CTB8000 CTB8000 BLUE BLUE BLUE WHI...

Страница 15: ...2 shake fast speed Gobo3 shake slow speed Gobo3 shake fast speed Gobo4 shake slow speed Gobo4 shake fast speed Gobo5 shake slow speed Gobo5 shake fast speed Gobo6 shake slow speed Gobo6 shake fast spe...

Страница 16: ...10 PAN 0 255 Pan movement range 540 Degrees 11 PAN FINE 0 255 12 TILT 0 255 Tilt movement range 270 Degrees 13 TILT FINE 0 255 14 FUNCTION 0 11 12 24 25 37 38 50 51 62 63 255 Unused range Fast defaul...

Страница 17: ...outdoor events for example If one or more of these factors is present inspect fixtures within their first 100 hours of oper ation to see whether cleaning is necessary Check again at frequent intervals...

Страница 18: ...fects instant open and black out Dimmer 0 100 Linear Dimmer Dynamic Effect Color Wheel 14 colors plus open rotation with variable direction and speed Static Gobo Wheel 17 gobos plus open wheel rotatio...

Страница 19: ...Power Supply Auto Ranging Electronic Switch Mode INCLUDED ITEMS 3 ft Power Con Power Cable User Manual Specifications are subject to change without notice For latest product specifications see www Glo...

Страница 20: ...LOSS OCCASIONED BY THE USE OF INABILITY TO USE OR RELIANCE ON THE INFORMATION CONTAINED IN THIS MANUAL THE GLOW LOGO THE SOLARIS LOGO THE GLOW PROFESSIONAL NAME THE SOLARIS PROFESSIONAL NAME AND ALL O...

Отзывы: