LED COLOR INDICATES
Flashing green
Normal operation. AC grid function is normal there is communication
with the Envoy.
Flashing orange
The AC grid is normal but there is no communication with the Envoy.
Flashing red
The AC grid is either not present or not within specification.
Solid red
There is an active “DC Resistance Low, Power Off” condition or “GFDI” fault.
To reset, refer to “DC Resistance Low – Power Off Condition” below.
The Microinverter LED
B.
As each module is installed, connect the Q Cable to the microinverter. Listen for a click as the
connectors engage.
Step 9. Manage the Cabling
Use cable clips to attach the cable to the module frame. Leave no more than 1.8 m (six feet)
between cable clips.
Step 10. Energize!
If applicable, turn ON the AC disconnect or circuit breaker for the branch circuit.
- Turn ON the main utility-grid AC circuit breaker. Your system will start producing power after a five-minute
wait time.
- Check the LED on the connector side of the microinverter.