Product information
3.1 Technical specifications
Log wood boiler
Log wood boiler
thermi
nator
II
18
27
36
49
60
Output
[kW]
18
27
36
49
60
Energy efficiency class
A+
A+
A+
A+
A+
Dimensions
Total depth
[cm]
120
120
130
151
151
Depth without fan (D)
[cm]
104
104
115
136
136
Width without ignition device (W)
[cm]
62
62
67
83
83
Height incl. adjustable feet
[1]
[cm]
155
155
166
167
167
Minimum room height
[2]
[cm]
168
168
186
186
186
Weight
Weight
[kg]
534
534
652
777
777
Water side
Water content
[l]
90
90
126
188
188
Maximum operating pressure
[bar]
3
3
3
3
3
Boiler flow/boiler return connection
[“]
External
thread 5/4
External
thread 5/4
External
thread 5/4
External
thread 6/4
External
thread 6/4
Drain connection
[“]
External
thread 1/2
External
thread 1/2
External
thread 1/2
External
thread 1/2
External
thread 1/2
Connection for thermal overload protection
[“]
External
thread 1/2
External
thread 1/2
External
thread 1/2
External
thread 1/2
External
thread 1/2
Immersion sleeve for the temperature sensor
of the thermal overload protection
[“]
Internal
thread 1/2
Internal
thread 1/2
Internal
thread 1/2
Internal
thread 1/2
Internal
thread 1/2
Flow rate / differential pressure at ΔT 10°K
[kg/h]
[hPa]
1550
4.9
2310
8.8
3090
15.7
4199
26.3
5140
35.6
Flow rate / differential pressure at ΔT 20°K
[kg/h]
[hPa]
770
1.8
1160
2.1
1540
4.0
2097
6.9
2570
9.4
Fuel
Fuel
Log wood/beech
Filling chamber opening WxH
[cm]
34x24
34x24
39x24
54x24
54x24
Filling chamber capacity for log wood
[l]
145
145
186
290
290
Maximum log wood length
[cm]
56
56
56
66
66
Flue gas side
Flue gas pipe diameter
[cm]
13
13
15
20
20
Height to centre of flue gas pipe
[1]
[cm]
78
78
88
90
90
Minimum draught requirement
[3]
[Pa]
5
5
5
5
5
Maximum flue gas temperature
[4]
[°C]
140
140
140
140
140
Emissions according to test report: Log
wood mode
Flue gas value
[5]
from test report:
Test institute / test report no.
TÜV Austria / 10-
UW-Wels-EX-
029-3
TÜV Austria / 13-
U-500/SD
TÜV Austria / 12-
UW-Wels-EX-
127-1
TÜV Austria / 12-
UW-Wels-EX-127
BLT / 042-06
CO full load
[mg/m³]
158
118.5
79
99.7
191
NO
X
full load
[mg/m³]
114
119.5
125
131.3
133
Org. C full load
[mg/m³]
4.4
3.2
2
2
4
Dust content full load
[mg/m³]
8
11
14
14.9
14
Flue gas mass flow full load
[g/s]
10
14.1
20.2
26.3
31.5
[1]
Adjustable feet at maximum depth of thread
[2]
The minimum room height is required for maintenance work
[3]
A draught stabiliser must be fitted if the specified draught of 15 Pa is exceeded (attention: In the case of a boiler with room-sealed
operation, use a room-sealed draught stabiliser)
[4]
The maximum flue gas temperature can be adjusted electronically
[5]
Flue gas values in mg/m³ are based on 13% O
2
of the volume flow
Содержание Therminator II
Страница 39: ...Annex Installation manual therminator II touch 39 9 6 Commissioning log ...
Страница 40: ...Annex 40 Installation manual therminator II touch ...
Страница 41: ...Annex Installation manual therminator II touch 41 9 7 Customer service order form ...
Страница 42: ...Annex 42 Installation manual therminator II touch ...
Страница 43: ...Annex Installation manual therminator II touch 43 ...