
Installation
26
Installation manual
thermi
nator
II touch
5.9.7
Service
The intermediate pellet store and its components are maintenance-free.
5.9.8
Settings in the SOLARFOCUS boiler control unit
Attention!
When commissioning the intermediate pellet store 110L, adjust the parameters in the screen below
as specified. Failure to observe this will lead to malfunction.
Make the following selection.
Fig. 5-10_01-114-02
5.10 Ash pan
5-11_001
Mount 2 x handles
1
with cylinder head screw
2
and nut
3
on the ash pan
4
.
Use ash pan only during boiler cleaning, never
place permanently in the combustion chamber.
5.11 Fuel chute
5-12_001AJ
Adjust the inclination of the fuel chute mounted in
the filling chamber (with hex bolts
1
) so that the
fuel is conveyed onto the middle of the stainless
steel combustion grate.
=
=
Содержание Therminator II
Страница 39: ...Annex Installation manual therminator II touch 39 9 6 Commissioning log ...
Страница 40: ...Annex 40 Installation manual therminator II touch ...
Страница 41: ...Annex Installation manual therminator II touch 41 9 7 Customer service order form ...
Страница 42: ...Annex 42 Installation manual therminator II touch ...
Страница 43: ...Annex Installation manual therminator II touch 43 ...