5 Installation
Note: The standard intake line (scope of supply) has
a diameter of 80 mm and is 1 m long (can be exten-
ded to a maximum of 3 m). To extend the line further
(an additional length of 8 m is possible), the diameter
must be increased to 100 mm.
Mount aluminium hose and feeder sensor
►
Mount aluminium
ηοσε ∅
80 mm
1
on the
connecting pipes, fix with clamps.
►
Insert feeder sensor
2
into the RS air distribution
box as far as it will go.
Abb. 2-19
Boiler-controlled room air damper in the RS line
(optional)
Function: When the burner is switched off, the dam-
per closes to prevent any exchange of air inside the
RS line.
Abb. 2-20: Actuation of a room air damper
►
Connect the room air damper to the boiler power
element at X6 (230 V AC).
►
For the parameter
Reserve relay
, select the
value
External boiler
.
The parameter
Reserve relay
is located in the
Ser-
vice menu
>
External boiler
.
5.3 Establishing the chimney connection
See instructions for execution
5.3.1 pellet
elegance
Flue gas pipes: Overview
pellet
elegance
10 and 15
Abb. 2-21
1 ID fan
2
Pipe Ø80 mm, length = 500 mm
(Art. 66552NIRO, optional accessory)
3
Extension from Ø80 mm to Ø100 mm
(Art. 97013, included in the scope of delivery of the boiler)
4
Extension from Ø100 mm to Ø130 mm
(Art. 66556NIRO, optional accessory)
pellet
elegance
20 and 24
Abb. 2-22
1 ID fan
2
Pipe Ø100 mm, length = 250 mm
–
Art. 66574NIRO, optional accessory;
–
This article is included in the extension pack Art.
66553NIRO
3
Pipe Ø100 mm, length = 500 mm
–
Art. 66575NIRO, optional accessory
–
This article is included in the extension pack Art.
66553NIRO
4
Extension from Ø100 mm to Ø130 mm
(Art. 66556NIRO, included in the scope of delivery of the boi-
ler)
20
Installation manual
pelletelegance