![SolarEdge SE5000H-AU Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/solaredge/se5000h-au/se5000h-au_installation-manual_1313740045.webp)
Status:
The inverter operation status: Off, Not Paired, Night Mode, Error, Pairing, or
Production.
Switch
: Indicates the position of the inverter ON/OFF/P switch: On, Off, or P
position.
CosPhi
: Indicates the ratio between active and reactive power.A negative value
indicates a lagging CosPhi.
For more information, refer to the
Power Control Application
Note, available on the SolarEdge website at
https://www.solaredge.com/sites/default/files/application_note_
power_control_configuration.pdf
Limit
: The inverter maximum output power
Country
: The selected country and grid setting
Voltage (Vdc)
: The DC input voltage
Temp
(°C or °F): The inverter heat sink temperature
Chapter 5: Activating, Commissioning and Configuring the System
44
EV Charging Single Phase Inverter MAN-01-00629-1.2
Содержание SE5000H-AU