a. Lift the inverter from the sides, or hold it at the top and bottom of the inverter
to lift the unit into place.
b. Lower the inverter onto the U-shaped indentations, as shown below. Let the
inverter lay flat against the wall or pole.
c. Insert the two supplied screws through the outer heat sink fin on both sides of
the inverter and into the bracket. Tighten the screws with a torque of 4.0 N*m /
2.9 lb.*ft.
Figure 11: Hanging the inverter on the brackets
6. Optionally, secure the Connection Unit bracket to the wall/pole, using 3 screws:
NOTE
In case of inverter replacement with the Connection Unit still mounted, it is
recommended to use all 3 holes.
a. Mark the location of the bracket screw for the Connection Unit, and optionally
the two additional bracket holes.
Figure 12: Connection Unit bracket
b. Remove the inverter from the wall/ pole.
c. Drill the hole for the Connection Unit bracket.
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5
28
Mounting the Inverter