Chapter 5: User Interface
SolarEdge Installation Guide - MAN-01-00060-2.6
39
Statute of the energy meter
Displays the total energy produced during the last day, month, year and since installation of the inverter.
J our [W]:
0. 0
M onth [KW h]:
0. 0
A nn e e [KW h]: 0. 0 T otal [KW h]: 0. 0
If an electricity meter is connected to the inverter, the following status screen is displayed with an indication of the total energy
reading:
C ompteur S tatus: <OK> <M essage S rreur> T otal [W h]:
XXXXXXX
•
Status:
Displays OK if the meter communicates with the communication card.
Status:
Displays OK if the meter communicates with the communication card.
•
<Error Message>:
If an error of the internal counter is displayed here, contact SolarEdge support.
<Error Message>:
If an error of the internal counter is displayed here, contact SolarEdge support.
•
Total (Wh)
The power reading by the counter. The value displayed in this line depends on the type of meter
Total (Wh)
The power reading by the counter. The value displayed in this line depends on the type of meter
connected to the inverter and its location:
•
If a bidirectional counter is connected to a consumption point, this value is the energy consumed.
•
If the meter is installed at the point of production of connection, this value is the energy produced by the site.
•
If the meter is installed at the connection point to the network, this value is the energy supplied to the network.
If the inverter is connected to the SolarEdge server, this value will also be displayed in the monitoring portal.
NOTE :
The accumulated data according to the internal real-time clock.
Status Telemetry
This window shows the last telemetry received from the power optimizer. The display changes each telemetry
transmission by a power optimizer.
To verify the correct operation of the installation, the installer can check the telemetry window for a certain period in
order to observe the reporting process of the power optimizers.
M odule #:
0 0 0 C 1 ED 9-0 3
Energy E [W h]:
0
V dc _ O [v]:
4 0. 5
V dc _ I [v]:
September 2. 5
•
Module #:
Serial number of the power optimizer
Module #:
Serial number of the power optimizer
•
Energy:
Energy power optimizer
Energy:
Energy power optimizer
•
Vdc_O:
output voltage of the power optimizer
Vdc_O:
output voltage of the power optimizer
Vdc_O:
output voltage of the power optimizer
•
Vdc_I:
input voltage of the power optimizer (Module voltage)
Vdc_I:
input voltage of the power optimizer (Module voltage)
Vdc_I:
input voltage of the power optimizer (Module voltage)