Connect ONLY to Gen Comm #1 port on the front of the HyPR and the Auto Generator Control port
on the TQG using a TQG Gen Comm Cable. A Solar Stik Remote-start Enabling Kit (RsEK) must be
installed on a TQG to communicate with the HyPR.
Figure 27. MEP-831A and MEP-802A Gen Comm Cable connections
HyPR GEN COMM Port Specificity
The two (2) GEN COMM ports are not equivalent. Their specificity is as follows:
• Defender or Ranger single operation
– Connect to Gen Comm #1 or #2 port.
• Defender/Ranger MPG tandem operation
– Connect to Gen Comm #1 and #2 ports. (Use 120
VAC Parallel Power Cable.)
• Tactical Quiet Generator (TQG)
– Connect ONLY to Gen Comm #1 port.
The Gen Comm Cables
for these generators
have a 10-pin connector
on the HyPR end and a
4-pin connector on the
generator end.
MEP-802A 5 kW
MEP-831A 3 kW
Gen Comm ports
Generator Type
selection switch
HyPR 3000