5.

 

Communication 

 

5.1

 

Physical connection CANBUS interface devices communicate to each 
other over CANBUS interface. This interface contains two pins: CAN 
HIGH and CAN LOW. All devices must be connected in parallel see 
Figure 9  

 

Only one termination resistor 120 Ohm must be connected for entire 
network. Each device has built in termination resistor which can be 
activated with jumper. For Bmspl this jumper is located on top of 

connector1 see Figure 7. In Figure 9 only Logger has active termination jumper. 

Table 1 Connectors pin map 

Connector 1(figure7) 

Connector 2 (figure7) 

Pin 

Function 

Pin 

Function 

CAN LOW 

5V aux power supply 2A max 

CAN HIGH 

General purpose input1. 

CAN GROUND 

General purpose input2. 

Bat + (51.2) pack voltage 

General purpose input3. 

5V aux power supply 2A max 

General purpose output1. 

Not connected 

General purpose output2. 

Not connected 

General purpose output3 

Ground 

Ground 

Figure 9 CANBUS architecture 

 

Содержание mypower24

Страница 1: ...Solar MD Proprietary Limited Company Registration 2014 169938 07 T 021 555 2181 E info solarmd co za W www mypower24 co za QUICK INSTALLATION MANUAL SS106 advanced Lithium Ion battery Mypower24 3 7k...

Страница 2: ...anical relay NO Number of battery modules 1 module Com isolation Yes 800V Weight of MSS 34kg Transportation protection Yes Operating voltage 44 8V 55 6Vdc Indicator Led programable Communication CAN A...

Страница 3: ...the way down until the limiting notch hit the end Tight the screw with big flat screwdriver 3 Mechanical installation 3 1 Box bracket assembly Figure 2 bracket assembly 3 2 Box mounting Please use th...

Страница 4: ...re starts call the fire department immediately The only extinguisher that will work on a Lithium ion Battery fire is a Class D Fire Extinguisher or Dry Sand or Dry Table Salt As shown in Fig 5 the dri...

Страница 5: ...e 6 Top clearance The top side of the box is clear for drilling in entire section Avoid using long drill bits clearance is 57mm shown in figure 6 4 Electrical installation Step 1 Before connecting any...

Страница 6: ...can be harmful for human Connecting main battery terminal must be with right size cable based on the rated current of the battery the charger inverter in case it is lower Use only 5mm hole diameter fo...

Страница 7: ...has built in termination resistor which can be activated with jumper For Bmspl this jumper is located on top of connector1 see Figure 7 In Figure 9 only Logger has active termination jumper Table 1 C...

Страница 8: ...ommunication Canbus status LED is OFF after everything is connected 1 Check that the other devices are switched ON 2 Check that only one termination resistor is enabled on the bus 3 Check cable connec...

Отзывы: