1.

 

Specification 

2.

 

Product overview 

 

 

 

mypower24 3.7k SS106 specification 

   

 

Battery type 

Lithium Iron Phosphate 

Scalability 

Up to 22 KWh 

Battery module 

SS106 

Communication 

CANBUS 500kbps/CAN 

2.0B 

Rated battery capacity 

3.84 kWh 

CANBUS termination 

Single 120 Ohm 

Output power 

Max 5 kW 

Canbus id range: 

256 - 499 

Usable battery energy 
@0.3C 

3.7 kWh 

Protection method 

Cell level: uv / ov 

Nominal voltage 

51.2V 

Protection phy 

Mechanical relay NO 

Number of battery modules 

1 module 

Com isolation 

Yes 800V 

Weight of MSS 

34kg 

Transportation 
protection 

Yes 

Operating voltage 

44.8V-55.6Vdc 

Indicator 

Led, programable 

Communication 

CAN 

Addition IO 

3 GPO 

Dimension enclosure 
Albro6: h/w/d 

600mm/400mm/200mm 

Configuration method 

Over mypower24 web 

portal 

Dimensions of SS106: 
h/w/d 

500mm/320mm/150mm 

Cell balancing 

Passive balancing 

Net Weight of SS106 

35 Kg 

Health monitoring 

Cycle counters and state 

of health 

Battery cycle life [+25 ‘C]

 

> 4000 

AUX power output  

5V 2A max 

Charging efficiency 

99% 

Storage duration 

6 25’C

 

Operating temperature 

-

5’C ~+50’C

 

Safety standard 
compliance 

IEC 62619/UN 

38.3/UL1642 

Transport 

UN3480 & UN38.3 

 Cell Certificate 

TUV / CE / RCM / 

UL1642 

IP level 

IP65 

 

 

Содержание mypower24

Страница 1: ...Solar MD Proprietary Limited Company Registration 2014 169938 07 T 021 555 2181 E info solarmd co za W www mypower24 co za QUICK INSTALLATION MANUAL SS106 advanced Lithium Ion battery Mypower24 3 7k...

Страница 2: ...anical relay NO Number of battery modules 1 module Com isolation Yes 800V Weight of MSS 34kg Transportation protection Yes Operating voltage 44 8V 55 6Vdc Indicator Led programable Communication CAN A...

Страница 3: ...the way down until the limiting notch hit the end Tight the screw with big flat screwdriver 3 Mechanical installation 3 1 Box bracket assembly Figure 2 bracket assembly 3 2 Box mounting Please use th...

Страница 4: ...re starts call the fire department immediately The only extinguisher that will work on a Lithium ion Battery fire is a Class D Fire Extinguisher or Dry Sand or Dry Table Salt As shown in Fig 5 the dri...

Страница 5: ...e 6 Top clearance The top side of the box is clear for drilling in entire section Avoid using long drill bits clearance is 57mm shown in figure 6 4 Electrical installation Step 1 Before connecting any...

Страница 6: ...can be harmful for human Connecting main battery terminal must be with right size cable based on the rated current of the battery the charger inverter in case it is lower Use only 5mm hole diameter fo...

Страница 7: ...has built in termination resistor which can be activated with jumper For Bmspl this jumper is located on top of connector1 see Figure 7 In Figure 9 only Logger has active termination jumper Table 1 C...

Страница 8: ...ommunication Canbus status LED is OFF after everything is connected 1 Check that the other devices are switched ON 2 Check that only one termination resistor is enabled on the bus 3 Check cable connec...

Отзывы: