background image

7

4.  Safety 

Please ensure all necessary measures are taken to prevent accidents. The use of SF modules in applications that may endanger  
human lives is prohibited, including in air and road transport systems. SF modules must not be used for anything other than their 
expressed purpose.
Solar Frontier strongly advises you to follow the instructions below in order to avoid bodily injury, damage to property and/or death.

4.1  General Safety

 • Installation, wiring, and maintenance of SF modules must only be carried out by licensed and trained persons.

 • Ensure that all instructions and information related to SF modules and other balance of system components are fully  

understood prior to handling and installing a PV solar system.

 • Wear appropriate protection and take all necessary precautions to prevent electric shock, especially when DC voltage  

exceeds 30 VDC.

 • The front surface of SF modules shall be covered with an opaque material during installation to decrease the  

potential of electrical shock.

 • SF modules only generate direct current (DC) electricity.

 • SF modules do not have the ability to store electricity.

 • SF modules will experience higher voltage when connected in series and higher electrical current when connected in parallel.

 • Only interconnect SF modules with similar electrical characteristic in series or in parallel to prevent system  

imbalance conditions and module damage.

 • The PV array open-circuit voltage must never exceed the maximum system voltage (including in low temperature conditions).

 • Leakage currents could create a shock hazard or fire.

 • Do not disconnect operational modules or electrical arcing may occur. This may result in serious bodily harm or death.

 • Do not use SF modules for purposes other than terrestrial power generation to prevent electrical shock,  

fire or other accidents.

 • Do not artificially concentrate sunlight on modules using lenses or mirrors.

 • Do not use any light sources other than natural sunlight and general illumination for power generation

 • Do not use SF modules in water or liquid. There is a serious risk of electric shock, an electric leak or an accident.

 • The level of leakage current must be limited in accordance with local regulations for safety reasons.

 • Carefully check the polarity of the wiring before installing. Incorrect wiring may damage SF modules or appliances.

 • Only use equipment, connectors, wiring and support frames suitable for solar electric systems.

5.  Storage and Transport

Please follow the instructions on the module packaging when storing and transporting SF modules. Ensure that each module is ad-
equately supported and always stored in dry conditions. The module packaging is not waterproof material. Keep the wiring box (junc-
tion box) and the module connector away from any liquids when storing and transporting SF modules. SF modules should be kept 
in the original packaging until final installation. Small amounts of white powder from packaging material may adhere to the modules. 
This may safely be ignored and has no affect on performance.

Содержание SF140-S

Страница 1: ...Solar Frontier Europe GmbH Data Sheet and Installation and Maintenance Manual SF140 S SF145 S SF150 S SF155 S SF160 S SF165 S SF170 S ENGLISH...

Страница 2: ...2...

Страница 3: ...id from August 2013 It replaces all previous changes made to this document Content 1 About this Manual 4 2 General Information 4 3 Technical Data 4 3 1 Electrical Characteristics 4 3 2 Module Performa...

Страница 4: ...SF155 S SF160 S SF165 S SF170 S Nominal power Pmax 140 W 145 W 150 W 155 W 160 W 165 W 170 W Power tolerance 5 W 0 W Open circuit voltage Voc 107 0 V 107 0 V 108 0 V 109 0 V 110 0 V 110 0 V 112 0 V S...

Страница 5: ...hould not exceed 7 A under any circumstances UL Modules installed in parallel will be provided with the listed maximum series fuse as specified 3 5 Mechanical Data Dimensions L x W x H 1 257 x 977 x 3...

Страница 6: ...5 31 1 225 31 1 225 30 12 13 5 35 35 30 372 5 372 5 454 5 454 5 566 5 598 5 5 934 2 21 5 21 5 548 5 120 35 0 5 977 2 90 444 28 2 568 5 5 Mounting holes 2 x Grounding 2 x 4 4 x 8 5 4 x 6 6 Mounting hol...

Страница 7: ...circuit voltage must never exceed the maximum system voltage including in low temperature conditions Leakage currents could create a shock hazard or fire Do not disconnect operational modules or elect...

Страница 8: ...temperature range indicated in the module s technical specifications 6 3 Module Handling Instructions Do not disassemble or modify SF modules This may result in an electric shock fire or other accide...

Страница 9: ...oduction Modules can be installed horizontally landscape or vertically portrait Maintain a space between SF modules and the roof This will allow air to circulate cooling the module and allowing conden...

Страница 10: ...0 Pa 50 lbs ft2 to the front and back of the module UL 1 600 Pa 33 4 lbs ft2 to the front and back of the module 1 5 times the design load is applied to the module during UL testing 2 400 Pa 50 lbs ft...

Страница 11: ...inimum TUV 2 400 Pa 50 lbs ft2 to the front and back of the module UL 1 600 Pa 33 4 lbs ft2 to the front and back of the module 1 5 times the design load is applied to the module during UL testing 2 4...

Страница 12: ...module overlap min 8 mm 8 mm 3 mm 3 mm 256 mm 75 mm 745 mm 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm 75 mm 745 mm 256 mm 75 mm 75 mm 75 mm 75 mm Array Installation section Landscape...

Страница 13: ...g cautions Be aware of the necessary grounding requirements prior to installation Your local authorities can help you further Install arrestors surge absorbers or any other appropriate lightning prote...

Страница 14: ...r Cables drooping from the terminal box are hazardous and must be avoided Cables should be secured so they are not exposed to direct sunlight such as behind the module The sum of Voc of modules in ser...

Страница 15: ...ny other hard materials use only soft cloths or sponges for removing dirt from the SF modules surface When replacement parts are required be sure the installer servicer uses parts specified by the man...

Страница 16: ...iafilmplatz 8 82031 Gr nwald bei M nchen Germany Tel 49 89 92 86 142 0 Italy Solar Frontier Europe GmbH Sede Secondaria per l Italia Via Domenico Cotugno 49 A scala B 70124 Bari Italy Tel 39 080 90 21...

Отзывы: