A
VOIDING THE
R
ISK OF
E
LECTROCUTION
D
ANGER
: R
ISK OF ELECTROCUTION
• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death or serious personal injury due to electrocution if direct
burial-type cable is not used, or if improper digging occurs.
• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum
No. 8 AWG (8.4 mm
2
) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal
enclosures of electrical equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.
W
ARNING
:
• To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious
personal injury due to electrocution.
• Your spa is provided with a Ground Fault Circuit Interrupter for user and equipment protection. To ensure proper operation of
this important safety device, test according to the following instructions per electrical configuration.
Cord-Connected 115 Volt, 15 Amp Models:
The GFCI is located at the end of the power cord. Before each use, with the unit
operating, push the TEST button. The unit should stop operating. Push the RESET button. The spa should now return to normal
operation. If the interrupter does not perform in this manner, there may be an electrical malfunction and with it, the possibility of
an electric shock. Disconnect the power until the problem has been corrected.
Hard-Wired 115 Volt, 30 Amp Models:
The GFCI breaker, located inside the sub-panel, supplies all of the power to the spa.
Before each use, open the sub-panel and press the TEST button located on the sub-panel GFCI breaker. The breaker should snap
into the “tripped” position and the spa should stop operating. Reset the sub-panel GFCI breaker by completely flipping the
breaker switch down, into the off position. Then, flip the breaker switch up, into the on position. Power should be restored and
the spa should resume operation. If the breaker does not perform in this manner, there may be an electrical malfunction and with
it, the possibility of an electric shock. Disconnect the power until the problem has been corrected.
D
ANGER
: R
ISK OF ELECTRIC SHOCK
• Install at least 5 feet (1.5 m) from all metal surfaces. A spa may be installed within 5 feet of a metal surface if each metal surface is
permanently connected by a minimum No. 8 AWG (8.42 mm
2
) solid copper conductor attached to the wire ground connector on
5
™