08/2016
22
2a. Installation, radiant heater S1
(Heater type IR 05001, IR 05002) with T-bracket
Only approved for wall mounting!
• Secure the T-bracket (1) with the underlying silicone plate (2), while observing
the safety distances and safety instructions (see Appendix 2)
• Secure the T-bracket on the fastening surface with 2 screws according to the
following figure.
• Fit the adapter claw (6) on the T-bracket in accordance with the drawing, fit sa
-
fety washers between the T-bracket and adapter claw and screw in M6 socket
cap screws from outside into the T-bracket.
• Push the securing lugs (3) with the ring (4) from the left side into the dovetail
groove
• Tighten the 3.5 x 6.5 screw (5).
• Attach the radiant heater S1 centrally on the adapter claw and adjust the poise.
• Use a 5 mm Allen key to tighten the eccentric tensioner (7)in a clockwise direc
-
tion; each adapter claw must be firmly connected to the heater and free from
play.
• Fit each ring (4) of the securing lug into the cutout (A)
• To set or adjust the direction of radiation, use a 5 mm Allen key to loosen
the screws (11), shift the heater into the required direction and re-tighten the
screws (11).
Heater type
Power
Wall installation
Ceiling installation
Horizontal
Vertical
Horizontal
Inclined
IR 05001
1400 W
IR 05002
2000 W
GB
9
15
6
52
1
2
6
3,4,5
B
7
A
11
12
220
Содержание IR 05001
Страница 7: ...08 2016 7 DE Hammernut immer oben Seite B Seite A ...
Страница 21: ...08 2016 21 Hammer groove always up Side B Side A GB ...
Страница 30: ......
Страница 37: ...08 2016 37 Groef altijd bovenup Zijde B Zijde A NL ...
Страница 46: ......
Страница 53: ...08 2016 53 Boulon à expansion toujours vers le haut Côté B Côté A FR ...