INTRODUCTION
The Solaira SMaRT 34-DV Variable Control has been engineered to work with Infrared Heaters, with a
maximum rating of 8.0kW @ 208-240V or 4.0kW @ 120V.
The Solaira SMaRT 34-DV Control has a 1 to 5 step setting allowing you to find the optimum comfort setting
in your specific area.
To increase output to full output, press and release red
button.
To increase in increments, press and hold the red
button until the desired number is reached.
To reduce output to OFF, press and release red
button.
To reduce in increments, press and hold the red
button until the desired number is reached
FEATURES
•
Weatherproof control for exposed, wet conditions (it is the electricians responsibility to assure correct
water tight connection, this may necessitate replacing included watertight strain relief)
•
Variable Control – Ability to adjust output to desired comfort level
•
Soft Start – zero current switching point which can extend emitter lamp life
•
Temperature Monitoring – Solaira SMaRT 34-DV Variable control is equipped with a local (on
controller) temperature monitor. This will allow user to pre-set the minimum temperature level that will
allow the controller to operate.
Note: the temperature monitor is calibrated in Celsius; please use the following table to aid in set up:
Fahrenheit
Celsius
Fahrenheit
Celsius
32.0
0.0
55.0
12.8
36.0
2.2
60.0
15.6
40.0
4.4
65.0
18.3
45.0
7.2
70.0
21.1
50.0
10.0
75.0
23.9
80.0
26.7
Infrared remote control interface which supports the Solaira SMaRT infrared remote control handset
(sold separately) which must be in line of sight of the controller.
Occupancy Sensor or Push button input (sold separately), which is used to re-trigger an internal "ON"
timer. The "ON" timer is configurable from 1-60 minutes by means of a trimmer potentiometer. If the
internal "ON" timer expires the load output is switched off.
Designed for optional remote, wired controller for use in dry, wall mount electrical box (sold
separately).
WARNING: Solaira SMaRT 34-DV Variable control is a high power
electrical device and MUST ONLY BE INSTALLED BY A CERTIFIED
ELECTRICIAN TO LOCAL AND NATIONAL ELECTRICAL CODE