background image

Trouble Shooting

 

 

 

 

 

 

Temperature Set Point 
Temperature set point allows user to control the 
MINIMUM TEMPERATURE for heaters to come 
on. If the ambient temperature is above the 
pre-set level, the heater control will show "t" and 
WIL NOT TURN ON. You can reduce the minimum 
temperature to 5⁰C 
 

Temperature Sensor Input 
For local temperature sensor input and optional remote 
temperature sensor input. The local temperature sensor 
is included with all SMaRT 34-DV controllers. If the user 
wishes NOT to use the temperature monitoring feature, 
simply disconnect the temperature sensor. 
 

FLASHING DOT ON CONTROL PANEL DISPLAY 
If the controller is used WITHOUT OPTIONAL OCCUPANCY SENSOR (PIR, Passive Infrared Sensor) or 
Pushbutton timer, then "wire jumper" must be installed in pins SIG and COM as shown. If the jumper is 
not installed, the controller senses an open circuit and will switch OFF. Your controller comes with the 
jumper installed and it should only be removed when a sensor or pushbutton timer is installed. 
 

Wire jumper installed for use 
WITHOUT optional Occupancy 
Sensor (PIR) 

Содержание SMaRT 34-DV

Страница 1: ...utlined on the heater label Maximum heater load SHOULD NOT EXCEED 38 AMPERE The unit must be externally fused The Controller MUST BE PROPERLY GROUNDED Ensure that the ground connection from the electr...

Страница 2: ...itoring Solaira SMaRT 34 DV Variable control is equipped with a local on controller temperature monitor This will allow user to pre set the minimum temperature level that will allow the controller to...

Страница 3: ...ional Occupancy Sensor sold separately it takes 60 seconds to set before detection takes place Optional Occupancy Sensor continues to monitor the area and will reset to the set time every time it dete...

Страница 4: ...SPECIFICATIONS Max load at 20 C ambient Voltage Power Consumption Occupancy Sensor option Pushbutton Timer option Set Time Period Temperature Set point Factory Set Temperature trip point 2 heater Ins...

Страница 5: ...SMaRT 34 DV ILLUSTRATIVE WIRING DIAGRAM WARNING SERIOUS INJURY OR DEATH COULD OCCUR DISCONNECT ALL POWER PRIOR TO SERVICE...

Страница 6: ...ith all SMaRT 34 DV controllers If the user wishes NOT to use the temperature monitoring feature simply disconnect the temperature sensor FLASHING DOT ON CONTROL PANEL DISPLAY If the controller is use...

Страница 7: ...website product information and products can be accessed from Canada and other countries around the world Customer understands that some or all products provided by Inforesight Consumer Products Inc m...

Отзывы: