17
Instruction Manual
INOXA SERIES
GB
English
GB
NOTE:
numbers shown below are referring to Fig. 1-2 chapter 6
COMMANDS DESCRIPTION to Page 4-5.
The welding current can be regulated from a distance in the TIG
mode using the MANUAL or FOOT remote control.
a) MANUAL remote control connection:
8.15 REMOTE CONTROL REGULATION
1.
For the connection use the
MANUAL REMOTE CONTROL ADAPTER
cod. V15190KI
15
of the machine to the set current on the display.
Ex. If the I2 set current is 200A, the regulation will be from 5A to
200A.
b) FOOT remote control connection:
1.
Connect the 7-pin Plug of the remote
control to the Receptacle (15).
The display will blink for a few seconds.
2.
Press the foot remote control to ignite
the welding arc and press it further to re-
gulate the current.
NOTA:
the welding current is regulated
from the minimum current of the machine
to the set current on the display.
Ex. If the I2 set current is 200A, the regu-
lation will be from 5A to 200A.
15
A
B
C
Manual
Remote
Control
Tig torch
2.
Connect the 7 poles plug of the remote control and the plug of
the button of the torch to the adapter, see (A) and (B) on fig.
3.
Connect the 7 poles plug (C) of the adapter to the socket (15)
of the machine. The display will flash for a few seconds.
4.
Set the welding current using the remote control.
NOTA:
the welding current is regulated from the minimum current
5
6
RELAY
MAX 1A
ROBOT
c) Automatic system connection:
On pin 5 and 6 of the 7 pin socket
there is the ARC ON signal.
The pins are shortcircuited by a
relay when the current is higher
then 3 amps with wich it is possible
to command a second party, such
as: rotative table, welding positio-
ner, robot etc.