214
39. SPECIFICATIONS
Atmospheric correction:
Temperature input range:
-35.0 to 60.0°C (in 0.1°C step)/ -31.0 to 140.0°F (in 0.1°F step)
Pressure input range:
500.0 to 1,400.0hPa (in 0.1hPa step)
375.0 to 1,050.0mmHg (in 0.1mmHg step)
14.80 to 41.30inchHg (in 0.01inchHg step)
Humidity input range:
0.0 to 100.0% (in 0.1% step)
ppm input range:
-499.9 to 499.9 ppm (in 0.1 ppm step)
Prism constant correction
-99.9 to 99.9 mm (in 0.1 mm step)
0 mm fixed for reflectorless measurement
Earth curvature and refraction correction
No/Yes K=0.142/Yes K=0.20 (selectable)
Scale factor setting
0.5 to 2.0
Sea level correction
No/Yes (selectable)
*1
: Slight haze, visibility about 20 km, sunny periods, weak scintillation.
*2
: No haze, visibility about 40 km, overcast, no scintillation.
*3
: Face the prism toward the instrument during the measurement with the distance at 10 m or less.
*4
: Figures when the laser beam strikes within 30° of the reflective sheet target.
*5
: Measurement at 50 to 60°C (122 to 140°F).
*6
: Figures when using Kodak Gray Card White side (reflection factor 90%), brightness level is less than
5,000 lx and the laser beam strikes orthogonally the White side.
*7:
Figures when using Kodak Gray Card White side (reflection factor 90%), brightness level is less than
500 lx and the laser beam strikes orthogonally the White side. (800 m or more)
*6,*7
:When performing reflectorless measurement, the possible measurement range and precision will
change depending on the target reflection factor, weather conditions and location conditions.
*8
:
Figures may differ according to the country or the area.
*9
: Accuracy is (2 + 2 ppm X D) mm for distance range 1.3 to 2 m.
*10
: Accuracy is (5 + 2 ppm X D) mm for distance range 0.3 to 0.66 m or less.
*11
: ISO 17123-4: 2012
*12
: Figures are as follows when EDM eco mode is selected. Fine measurement: less than 2.0 sec + every
0.9 sec or less, Rapid measurement: less than 1.8 sec + every 0.6 sec or less, Tracking measurement:
less than 1.8 sec + every 0.4 sec or less
Internal memory
Capacity
about 50,000 points
External memory
USB flash memory (up to 32 GB)
Data transfer
Data input/output
Asynchronous serial, RS232C compatible
USB
USB Revision 2.0 (High Speed), Host (Type A), Only a USB flash drive
is compatible.
Bluetooth
wireless technology (Option)
*13
Transmission method
FHSS
Modulation
GFSK (Gaussian-filtered frequency shift keying)
Frequency band
2.402 to 2.48GHz
Bluetooth
profile
SPP, DUN
Power class
Class 1.5
Usable range
about 10 m (while in communication with SHC500)
*14
*15
*13
:
Bluetooth
function may not be built in depending on telecommunications regulations of the country or the
area where the instrument is purchased. Contact your local dealer for the details.