165
30.REGISTERING/DELETING DATA
It is possible to register or delete coordinate data of the known points in the current JOB.
The coordinate data that has been registered can be output during setting for use as instrument station,
backsight station, known point, and setting-out point coordinate data.
• It is possible to register 50,000 items of coordinate data, including the data inside the JOBs.
• There are two registration methods: key entry and entry from an external instrument.
Communication cables: "38. ACCESSORIES"
Output format and command operations: "Communication manual"
• When entering known point data from an external device, iM does not check the repeated point name.
• Communication setup can be performed in the known data as well. Select “Comms Setup” in <Known data>.
• When “inch” is selected as the distance unit, the value must be input in “feet" or "US feet".
• Deleting each data does not free the memory. When a JOB is deleted, the occupied memory is freed.
PROCEDURE Using the key entry method to register known point coordinate data
1. Select “Known data” in Data Mode.
• Current JOB name is displayed.
2. Select “Key in coord” and input known point coordinates
and point name.
3. After setting the data, press
{ENT}
.
The coordinate data is recorded in the current JOB and
screen in step 2 is restored.
4. Continue to enter other known point coordinate data.
5. After the registration of all the coordinate data has been
completed, press
{ESC}
to restore <Known data>.
30.1 Registering/Deleting Known Point Data
Data
JOB
Known data
Code
PT
Known data
Job.JOB1
Key in coord
Deletion
Comms input
View
PT