13. RESECTION MEASUREMENT

56

&

Precaution when performing resection

In some cases it is impossible to calculate the coordinates of an unknown 
point (instrument station) if the unknown point and three or more known 
points are arranged on the edge of a single circle. 

An arrangement such as that shown below is desirable.

It is sometimes impossible to perform a correct calculation in a case such 
as the one below.

When they are on the edge of a single circle, take one of the following 
measures.

(1) Move the instrument station 

as close as possible to the 
center of the triangle.

(2) Observe one more known 

point which is not on the circle

(3) Perform a distance 

measurement on at least one 
of the three points.

G

• In some cases it is impossible to calculate the coordinates of the instrument 

station if the included angle between the known points is too small. It is difficult 
to imagine that the longer the distance between the instrument station and the 
known points, the narrower the included angle between the known points. Be 
careful because the points can easily be aligned on the edge of a single circle.

  : Unknown point
  : Known point

X130R.book  56 ページ  2003年10月8日 水曜日 午後12時53分

Содержание 130R Series

Страница 1: ...es130R SET1130R R3 SET2130R R3 SET3130R R3 SET4130R R3 Reflectorless Total Station OPERATOR S MANUAL SET1130R3 2130R3 3130R3 4130R3 CLASS 3R Laser Product SET1130R 2130R 3130R 4130R CLASS 2 Laser Product X130R_C1C2 fm 1 ページ 2004年1月13日 火曜日 午前10時49分 ...

Страница 2: ... This is the mark of the Japan Surveying Instruments Manufacturers Association X130R_C1C2 fm 2 ページ 2003年10月14日 火曜日 午後8時17分 ...

Страница 3: ... refer to Interfacing with the SOKKIA SDR Electronic Field Book and Command Explanations manuals and ask your Sokkia agent The specifications and general appearance of the instrument may be altered at any time and may differ from those appearing in brochures and this manual Some of the diagrams shown in this manual may be simplified for easier understanding Series130R SET1130R R3 SET2130R R3 SET31...

Страница 4: ...R3 in this manual Screens and illustrations appearing in this manual are of SET2130R Location of softkeys in screens used in procedures is based on the factory setting It is possible to change the allocation of softkeys in Meas mode CWhat are softkeys 4 1 Parts of the Instrument Softkeys allocation 25 3 Allocating Key Functions Kodak Gray Card KODAK is a registered trademark of Eastman Kodak Compa...

Страница 5: ...tal Angle to a Required Value Horizontal Angle Hold 32 10 3 Horizontal Angle Repetition 33 10 4 Angle Measurement and Outputting the Data 34 11 DISTANCE MEASUREMENT 35 11 1 Returned Signal Checking 36 11 2 Distance and Angle Measurement 37 11 3 Recalling the Measured Data 38 11 4 Distance Measurement and Outputting the Data 39 11 5 REM Measurement 40 12 COORDINATE MEASUREMENT 42 12 1 Entering Inst...

Страница 6: ...more Points 81 18 2 Changing the Starting Point 83 19 SURFACE AREA CALCULATION 85 20 RECORDING DATA RECORD MENU 89 20 1 Recording Instrument Station Data 89 20 2 Recording Angle Measurement Data 91 20 3 Recording Distance Measurement Data 92 20 4 Recording Coordinate Data 93 20 5 Recording Distance and Coordinate Data 94 20 6 Recording Notes 95 20 7 Reviewing JOB Data 96 21 SELECTING DELETING A JO...

Страница 7: ...ING AND ERROR MESSAGES 132 27 CHECKS AND ADJUSTMENTS 136 27 1 Plate Level 136 27 2 Circular Level 137 27 3 Tilt Sensor 138 27 4 Collimation 142 27 5 Reticle 143 27 6 Optical Plummet 145 27 7 Additive Distance Constant 147 27 8 Guide Light 148 28 POWER SUPPLIES 152 29 TARGET SYSTEM 153 30 STANDARD EQUIPMENT 155 31 OPTIONAL ACCESSORIES 158 32 SPECIFICATIONS 162 33 REGULATIONS 167 34 EXPLANATION 170 ...

Страница 8: ...vi X130R book vi ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 9: ...ndication C WARNING Ignoring this indication and making an operation error could possibly result in death or serious injury to the operator C CAUTION Ignoring this indication and making an operation error could possibly result in personal injury or property damage J This symbol indicates items for which caution hazard warnings inclusive is urged Specific details are printed in or near the symbol D...

Страница 10: ...S E When securing the instrument in the carrying case make sure that all catches including the side catches are closed Failure to do so could result in the instrument falling out while being carried causing injury D Do not use the carrying case as a footstool The case is slippery and unstable so a person could slip and fall off it D Do not place the instrument in a case with a damaged catch belt o...

Страница 11: ...o recharge batteries Other chargers may be of different voltage rating or polarity causing sparking which could lead to fire or burns D Do not heat or throw batteries into fire An explosion could occur resulting in injury E To prevent shorting of the battery in storage apply insulating tape or equivalent to the terminals Otherwise shorting could occur resulting in fire or burns D Do not use batter...

Страница 12: ...d be injured if struck by the tripod shoes E Keep hands and feet away from the tripod shoes when fixing the tripod in the ground A hand or foot stab wound could result E Tighten the leg fixing screws securely before carrying the tripod Failure to tighten the screws could lead to the tripod legs extending causing injury D Do not perform disassembly or rebuilding Fire electric shock or burns could r...

Страница 13: ...tery cover terminal or connectors Contact with these parts may cause damage to the instrument Make sure that the inside of the carrying case and the instrument are dry before closing the case If moisture is trapped inside the case it may cause the instrument to rust The Lithium Battery The lithium battery a backup battery which retains data in the internal memory of the SET can back up data for ap...

Страница 14: ...ean the instrument before returning it to the case The lens requires special care First dust it off with the lens brush to remove tiny particles Then after providing a little condensation by breathing on the lens wipe it with the wiping cloth If the display is dirty carefully wipe it with a soft dry cloth To clean other parts of the instrument or the carrying case lightly moisten a soft cloth in a...

Страница 15: ...r reflective sheet is selected in Config mode as target Guide light optional function Class 1 LED Product G EDM device is classified as Class 3R Laser Product SET 1130R3 2130R3 3130R3 4130R3 Class 2 Laser Product SET1130R 2130R 3130R 4130R when reflectorless measurement is selected When the prism or reflective sheet is selected in Config mode as target the output is equivalent to the safer class 1...

Страница 16: ...eam does not stray from them SET 1130R3 2130R3 3130R3 4130R3 only CCaution Perform checks at start of work and periodic checks and adjustments with the laser beam emitted under normal conditions When the instrument is not being used turn off the power When disposing of the instrument destroy the battery connector so that the laser beam cannot be emitted Operate the instrument with due caution to a...

Страница 17: ...2130R3 3130R3 4130R3 only Read the Operator s manual for usage procedures for this product Hazardous protection procedures read this chapter Requisite protective gear read this chapter Accident reporting procedures stipulate procedures beforehand for transporting the injured and contacting physicians in case there are laser induced injuries Persons working within the range of the laser beam are ad...

Страница 18: ...mmet reticle cover 17 Optical plummet eyepiece 18 Horizontal clamp 19 Horizontal fine motion screw 20 Data input output connector 21 External power source connector 22 Plate level 23 Plate level adjusting screw 24 Vertical clamp 25 Vertical fine motion screw 26 Telescope eyepiece screw 27 Telescope focusing ring 28 Laser radiation warning indicator Not included on SET 1130R 2130R 3130R 4130R 29 Pe...

Страница 19: ... The height of the SET is 236mm from tribrach dish to this mark Instrument height is input when setting instrument station data and is the height from the measuring point where SET is mounted to this mark Laser pointer Function A target can be sighted with a red laser beam in dark locations without the use of the telescope Operation panel C 5 1 Basic Key Operation 1 X130R book 11 ページ 2003年10月8日 水曜...

Страница 20: ...er pointer is used and laser beam status can be known from the telescope eyepiece side Wireless keyboard Optional accessory C 5 1 Basic Key Operation and 31 OPTIONAL ACCESSORIES Laser radiation warning indicator Key panel Beam source Strap attachment hole A to Z Softkey selecting keys FUNC MEAS I SFT BS ESC A N X130R_04 FM 12 ページ 2004年1月8日 木曜日 午前9時18分 ...

Страница 21: ...ded into a red and a green light A poleman can ascertain the present position by checking the Guide light color Guide light status The Guide light indicator is lit when the Guide light is ON Light status Meaning Red From position of poleman Move target left Green From position of poleman Move target right Red and Green Target is at correct horizontal position Guide light Guide light indicator gree...

Страница 22: ... 2 Mode Diagram Note Stn data Dist Coord Dist Coord data Set out line Point projection S N Changing Password Date and time Press CNFG except during operation ESCAPE ESCAPE ESCAPE X130R_04 FM 14 ページ 2003年10月16日 木曜日 午後4時50分 ...

Страница 23: ...hing the target type in Config mode 25 1 EDM Settings zSwitching the Laser pointer Guide light optional function ON OFF CSelecting of laser pointer guide light optional function 25 1 EDM Settings After turning ON the Laser pointer Guide light the laser beam is emitted for 5 minutes and then automatically switches OFF But in the Status screen and when target symbol ex is not displayed in the Meas m...

Страница 24: ...en pages when more than 4 softkeys are allocated CNFG Config mode C 25 2 Configuration Config Mode Tilt C 7 2 Levelling PROCEDURE Levelling on the screen Aiming C 11 1 Returned Signal Checking SHIFT Switch between numerals and alphabetic characters 0 to 9 During numeric input input number of the key During alphabetic input input the characters displayed above the key in the order they are listed I...

Страница 25: ...nt to select using L K Switches between Prism Sheet and None 4 Press I or G to move to the next option The selection is set and you can set the next item zSwitching modes C 4 2 Mode Diagram O G Up and down cursor L K Right and left cursor Select other option I Accept the option CNFG From Status mode to Config Mode Configuration Mode MEAS From Status mode to Meas Mode Measurement Mode MEM From Stat...

Страница 26: ...yboard under heavy objects or in a tight space A key may be continuously depressed and deplete battery power Ni Cd batteries are recommended when operating the Wireless Keyboard under low temperatures In temperatures around 20 C the SET may function erratically if the Wireless Keyboard is operated too close to the SET Hold the Wireless Keyboard further away from the SET and at various angles to th...

Страница 27: ...d alphabetic characters A to Z During numeric input input numeral or symbol and printed above the key During alphabetic input input the character of the key BS Delete a character on the left ESC Cancel the input data SFT Switch between upper and lower case I Select accept input word value R U O G is printed above the key Up and down cursor numeric input mode V T L K is printed above the key Right ...

Страница 28: ...l angle CSwitching vertical angle display status 25 2 Configuration Config Mode ZA Zenith angle Z 0 VA Vertical angle H 0 H 90 To switch vertical angle slope in press ZA 3 Horizontal angle Press R L to switch the display status HAR Horizontal angle right HAL Horizontal angle left 6 Guide light pointer Laser is emited 8 F i n e 9 A Previous page Next page Input mode 9 OK X130R_05 FM 20 ページ 2003年10月...

Страница 29: ...target symbol is displayed prism reflective sheet reflectorless 6 Tilt angle compensation When this symbol is displayed the vertical and horizontal angles are automatically compensated for small tilt errors using 2 axis tilt sensor CTilt compensation setting 25 2 Configuration Config Mode 7 Laser pointer Guide light optional function display C Selecting Laser pointer Guide light 25 1 EDM Settings ...

Страница 30: ...nside of the instrument Periodically wipe clean the terminals on the SET with the cleaning cloth to keep them free of dirt XPROCEDURE Mounting the battery 1 Insert the battery by aligning the battery guide with the guide hole in the instrument 2 Press the top of the battery until you hear a click XPROCEDURE Removing the battery 1 While pressing the UNLOCK button press the release button downward 2...

Страница 31: ... over the surveying point Make sure the tripod shoes are firmly fixed in the ground 2 Install the instrument Place the instrument on the tripod head Supporting it with one hand tighten the centering screw on the bottom of the unit to make sure it is secured to the tripod 3 Focus on the surveying point Looking through the optical plummet eyepiece turn the optical plummet eyepiece to focus on the re...

Страница 32: ...osest to the offcenter direction of the bubble or by lengthening the tripod leg farthest from the offcenter direction of the bubble Adjust one more tripod leg to center the bubble 3 Center the bubble in the plate level Loosen the horizontal clamp to turn the upper part of the instrument until the plate level is parallel to a line between levelling foot screws A and B Center the air bubble using le...

Страница 33: ... of the plate level If the bubble is off center perform the following a Turn levelling foot screws A and B equally in opposite directions to remove half of the bubble displacement b Turn the upper part a further 90 and use levelling foot screw C to remove half of the displacement in this direction Or adjust the plate level C 27 1 Plate Level 6 Check to see if the bubble is in the same position in ...

Страница 34: ...eck again to make sure the bubble in the plate level is centered If not repeat the procedure starting from step 3 XPROCEDURE Levelling on the screen 1 Press ON to power on 2 Press to display the circular level on the screen z indicates bubble in circular level The range of the inside circle is 3 and the range of the outside circle is 6 Tilt angle values X and Y are also displayed on the screen 3 C...

Страница 35: ...el to a line between levelling foot screws A and B then tighten the horizontal clamp 5 Set the tilt angle to 0 using foot screws A and B for the X direction and levelling screw C for the Y direction 6 When levelling is completed press ESCAPE X130R book 27 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 36: ...ise then counterclockwise little by little until just before the reticle image becomes focussed Using these procedures frequent reticle refocussing is not necessary since your eye is focussed at infinity 2 Sight the target Loosen the vertical and horizontal clamps then use the peep sight to bring the target into the field of view Tighten both clamps 3 Focus on the target Turn the telescope focussi...

Страница 37: ...t image and the reticle Eliminating parallax This is the relative displacement of the target image with respect to the reticle when the observer s head is moved slightly before the eyepiece Parallax will introduce reading errors and must be removed before observations are taken Parallax can be removed by refocussing the reticle X130R book 29 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 38: ...ical circle by face left face right measurements 34 EXPLANATION After that Meas Mode screen appears If Out of range is displayed the instrument tilt sensor is indicating that the instrument is out of level Level the instrument once again and the horizontal and vertical angles will be displayed When Resume in Instr config is set to On the screen previous to power off is displayed C 25 2 Configurati...

Страница 39: ...ion XPROCEDURE 1 Sight the first target as at right 2 In the first page of the Meas mode screen press 0SET 0SET will flash so press 0SET again The horizontal angle at the first target becomes 0 3 Sight the second target The displayed horizontal angle HAR is the included angle between two points 10 1 Measuring the Horizontal Angle between Two Points Horizontal Angle 0 X130R book 31 ページ 2003年10月8日 水...

Страница 40: ...that is input as the horizontal angle is displayed 4 Sight the second target The horizontal angle from the second target to the value set as the horizontal angle is displayed Pressing HOLD performs the same function as above Press HOLD to set the displayed horizontal angle Then set the angle that is in hold status to the direction you require CAllocating HOLD 25 3 Allocating Key Functions 10 2 Set...

Страница 41: ...on 2 Sighting the first target press OK 3 Sighting the second target press OK 4 Sighting the first target a second time press OK 5 Sighting the second target a second time press OK The added value of the horizontal angle is displayed on the second line HARp and the average value of the horizontal angle is displayed on the fourth line Ave 10 3 Horizontal Angle Repetition Menu Coordinate S O Offset ...

Страница 42: ...lains angle measurement and the features used to output measurement data to a computer or peripheral equipment CCommunication cables 31 OPTIONAL ACCESSORIES Output format and command operations Interfacing with the SOKKIA SDR Electronic Field Book and Command Explanations manuals XPROCEDURE 1 Connect SET and host computer 2 Allocate the D OUT softkey to the Meas mode screen C 25 3 Allocating Key F...

Страница 43: ...t the target setting on the instrument matches the type of target used SET automatically adjusts the intensity of the laser beam and switches the distance measurement display range to match the type of target used If the target does not correspond to the target settings accurate measurement results cannot be obtained Accurate measurement results cannot be obtained if the objective lens is dirty Du...

Страница 44: ...herefore make sure that the target center is sighted correctly XPROCEDURE 1 Accurately sight the target 2 Press Aiming is displayed The intensity of the light of the returned signal is displayed by a gauge The more displayed the greater the quantity of reflected light If is displayed only enough light for the measurement is returned When is not displayed accurately resight the target Press BEEP to...

Страница 45: ... XPROCEDURE 1 Sight the target 2 In the first page of Meas Mode press DIST to start distance measurement When measurement starts EDM information distance mode prism constant correction value atmospheric correction factor is represented by a flashing light A short beep sounds and the measured distance data S vertical angle ZA and horizontal angle HAR are displayed 11 2 Distance and Angle Measuremen...

Страница 46: ...ce and angle that are most recently measured remain stored in the memory until the power is off and can be displayed at any time C 11 3 Recalling the Measured Data The distance and angle that are most recently measured remain stored in the memory until the power is off and can be displayed at any time The distance measurement value vertical angle horizontal angle and the coordinates can be display...

Страница 47: ...or peripheral equipment CCommunication cables 31 OPTIONAL ACCESSORIES Output format and command operations Interfacing with the SOKKIA SDR Electronic Field Book and Command Explanations manuals XPROCEDURE 1 Connect SET and host computer 2 Allocate the D OUT softkey to the Meas mode screen C 25 3 Allocating Key Functions 3 Sight the target point 4 Press D OUT and select Dist data to measure the dis...

Страница 48: ...in θ z1 x cot θ z2 S cos θ z1 XPROCEDURE 1 Set the target directly under or directly over the object and measure the target height with a tape measure etc 2 After inputting the target height accurately sight the target C Press DIST in page 1 of Meas Mode to carry out measurement The measured distance data S vertical angle ZA and horizontal angle HAR are displayed Press STOP to stop the measurement...

Страница 49: ... the target then press OBS 6 Press ESCAPE to finish measurement and return to the Meas mode screen It is also possible to perform REM measurement when REM on the Meas mode screen C 25 3 Allocating Key Functions Inputting target height Step 3 Press HT to set target height It can be set also in Stn data of coordinate measurement C 12 1 Entering Instrument Station Data REM Resection Area calculation ...

Страница 50: ...entered in advance EDM setting can be done in coordinate measurement menu CSetting items 25 1 EDM Settings Before coordinate measurement enter instrument station coordinates the instrument height and target height XPROCEDURE 1 First measure the target height and instrument height with a tape measure etc 2 Press COORD in the first page of the Meas mode screen to display Coord 12 1 Entering Instrume...

Страница 51: ...ou wish to read in the registered coordinate data press READ C PROCEDURE Reading in Registered Coordinate Data 4 Press OK to set the input values Coord is displayed again When REC is pressed instrument station data is saved C 20 RECORDING DATA RECORD MENU 0 000 READ REC OK REC OK Coord Stn Orientation Observation EDM X130R_12 FM 43 ページ 2004年1月8日 木曜日 午前9時20分 ...

Страница 52: ...B or in the Coordinate Search JOB Crd Stn Coordinate data saved in the current JOB or in the Coordinate Search JOB 2 Align the cursor with the required point number and press I The point number that was read in and its coordinate is displayed KL P Use O G to move from page to page KL P Use O G to select individual point Press TOP to move to the first point number on the first page Press LAST to mo...

Страница 53: ...OB is changed When SRCH is pressed SET searches data in the current JOB first then in the Coordinate Search JOB If more than two points with the same point name exist in the current JOB SET finds the newer data only Based on the instrument station coordinates and backsight station coordinates which have already been set the azimuth angle of the backsight station is calculated XPROCEDURE 1 Select S...

Страница 54: ...from memory press READ C 12 1 Entering Instrument Station Data PROCEDURE Reading in Registered Coordinate Data 3 Press OK Instrument station coordinates are displayed 4 Sight the backsight station then press YES to set the backsight station Coord is restored Press NO to go back to step 2 OK READ Null X130R book 46 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 55: ...ion point E coordinate Z Zenith angle fh Target height Z0 Station point Z coordinate Az Direction angle G Z zenith angle is calculated as 360 Z when the telescope is in the face left position if either the horizontal angle has been set to 0 by pressing 0SET or the required horizontal angle has been set by pressing H ANG If not measured or the space is left blank Null will be displayed If station p...

Страница 56: ...ht of the next target is different reenter the target height before beginning the observation REC records measurement results CRecording method 20 RECORDING DATA RECORD MENU 3 Sight the next target and press OBS to begin measurement Continue until all targets have been measured 4 When coordinate measurement is completed press ESCAPE to return to Coord Coord Stn Orientation Observation EDM C X130R_...

Страница 57: ...nate resection measurement overwrites the N E and Z data of the instrument station but height resection does not overwrite N and E Always perform resection measurement in the sequence described in 13 1 Coordinate Resection Measurement and 13 2 Height Resection Measurement Input known coordinate data and calculated instrument station data can be recorded in the current JOB C 21 SELECTING DELETING A...

Страница 58: ...l required known points have been set press MEAS When READ is pressed registered coordinates can be recalled and used C 12 1 Entering Instrument Station Data PROCEDURE Reading in Registered Coordinate Data Press ESCAPE to return to the previous known point 3 Sight the first known point and press DIST to begin measurement The measurement results are displayed on the screen When ANGLE has been selec...

Страница 59: ...d 7 Press RESULT to check the result If there are no problems with the result press ESCAPE and go to step 11 REC records measurement results CRecording method 20 RECORDING DATA RECORD MENU Press ADD when there is a known point that has not been measured or when a new known point is added 8 If there are problems with the results of a point align the cursor with that point and press BAD is displayed...

Страница 60: ... points or only the final point can be observed again 10 Press OK in the screen of step 6 to finish resection measurement The instrument station coordinate is set Press YES when you want to set the azimuth angle of the first known point as the backsight point Press NO to return to Meas Mode without setting the azimuth angle It is also possible to perform resection measurement when RESEC on Meas mo...

Страница 61: ...n set press MEAS Press ESCAPE to return to the previous known point 3 Sight the first known point and press OBS to begin measurement The measurement results are displayed on the screen 4 Press YES to use the measurement results of the first known point 5 If measuring two or more known points repeat procedures 3 to 4 in the same way from the second point When the minimum quantity of observation dat...

Страница 62: ...with that point and press BAD is displayed on the left of the point 9 Press RE CALC to perform calculation again without the point designated in step 8 The result is displayed If there are no problems with the result go to step 10 If problems with the result occur again perform the resection measurement from step 3 10 Press OK to finish resection measurement Only Z elevation of the instrument stat...

Страница 63: ...s are found using angle and distance observation equations and the instrument station coordinates are found using the method of least squares The Z coordinate is found by treating the average value as the instrument station coordinates X130R book 55 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 64: ...easures 1 Move the instrument station as close as possible to the center of the triangle 2 Observe one more known point which is not on the circle 3 Perform a distance measurement on at least one of the three points G In some cases it is impossible to calculate the coordinates of the instrument station if the included angle between the known points is too small It is difficult to imagine that the ...

Страница 65: ...difference S H V distances are calculated from the read in setting out coordinate instrument station data instrument height and target height Setting out measurement can be carried out effectively using the Guide light C 4 1 Parts of the Instrument 5 1 Basic Key Operation and 31 OPTIONAL ACCESSORIES EDM settings can be set in the Setting out measurement menu If not measured or the space is left bl...

Страница 66: ...e of the Meas mode screen to display S O 2 Enter the instrument station data C 12 1 Entering Instrument Station Data PROCEDURE Reading in Registered Coordinate Data 3 Set the azimuth angle of the backsight point C 12 2 Azimuth Angle Setting steps 2 to 6 4 Select S O data 14 1 Distance Setting out Measurement S O Stn Orientation Observation EDM S O data X130R book 58 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 67: ...12 1 Entering Instrument Station Data PROCEDURE Reading in Registered Coordinate Data 6 Set the following items 1 Sdist Hdist Vdist distance from the instrument station to the position to be set out 2 H ang included angle between the direction of the reference and the point to be set out Pressing COORD in the second page allows you to enter the coordinates of the point to be set out 7 Press OK to ...

Страница 68: ...s 0m If S O H is move the prism toward yourself if it is move the prism away from yourself By pressing an arrow pointing to the left or right displays which direction the target should be moved Move the prism to left Move the prism to right Move the prism forward Move the prism away When the target is within measurement range all four arrows are displayed C OBS S O N REC C C X130R book 60 ページ 2003...

Страница 69: ...int to be set out the SET calculates the setting out horizontal angle and horizontal distance By selecting the horizontal angle and then the horizontal distance setting out functions the required coordinate location can be set out To find the Z coordinate attach the target to a pole etc with the same target height XPROCEDURE 1 Press S O on the third page of the Meas mode screen to display S O 14 2...

Страница 70: ... be recalled and used as setting out coordinates C 12 1 Entering Instrument Station Data PROCEDURE Reading in Registered Coordinate Data 6 Press OK to set the setting out data 7 Press OBS to begin coordinate setting out measurement Move the prism to find the point to be set out C 14 1 Distance Setting out Measurement steps 9 to 10 Move the prism upward H Move the prism downward 8 Press ESCAPE to r...

Страница 71: ... from the surveying point to the target 2 Press S O in the Meas mode screen to display S O 3 Enter the instrument station data C 12 1 Entering Instrument Station Data PROCEDURE Reading in Registered Coordinate Data 4 Select S O data and press NS O until S O Ht is displayed 5 Input height from the surveying point to the position to be set out in SO dist 6 After inputting the data press OK 14 3 REM ...

Страница 72: ...e the telescope to find the point to be set out C 14 1 Distance Setting out Measurement steps 9 to 10 Move the telescope near the zenith H Move the telescope near the nadir 8 When the measurement is completed press ESCAPE to restore S O REM C X130R book 64 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 73: ...tes and the observed coordinates When not observing first or second points scale factor is set to 1 Defined baseline can be used in both setting out line measurement and point projection XPROCEDURE 1 In the second page of Meas mode screen press MENU then select Set out line 15 1 Defining Baseline Scale X Y Hdist horizontal distance calculated from the measured value Hdist horizontal distance calcu...

Страница 74: ...t data and press OK 5 Enter the second point data 6 Press FUNCTION MEAS is displayed When not observing the first point and the second point go to step 13 7 Press MEAS on the screen of step 7 to move to observation of the first point D e f i n e 1 s t P t N p E p Z p 1 2 1 2 2 11 3 4 6 4 9 1 0 8 8 READ REC OK Stn Orientation Define baseline Set out line Set out line D e f i n e 2 n d P t N p E p Z...

Страница 75: ... coordinates of two points and the scale factors are displayed 12 Press OK on the screen of step 12 to define the baseline Set out line is displayed Move to setting line measurement C 15 2 Setting out Line Point 15 3 Setting out Line Line Press Sy 1 to set scale factor y to 1 Press 1 to change the grade display mode to 1 elevation horizontal distance M e a s u r e 1 s t P t OBS 1 2 1 2 2 1 1 3 4 6...

Страница 76: ...ut line 2 Set the following items 1 Length Distance along the baseline from the first point to the position at which a line extending from the required point intersects the baseline at right angles X direction 2 Offset Distance from the required point to the position at which a line extending from the required point intersects the baseline at right angles Y direction 15 2 Setting out Line Point Ba...

Страница 77: ...asurement repeat steps from 4 Setting out line line measurement tells how far horizontally the measured point is from the baseline and how far vertically the measured point is from the connected line The baseline can be offset in a horizontal direction if necessary Before performing setting out line line the baseline must be defined 15 3 Setting out Line Line S e t o u t l i n e 12 024 94 675 R E ...

Страница 78: ...alue and left side indicates negative value When not setting offset value go to step 3 3 Sight the target and press OBS on the screen of step 2 The measurement results are displayed on the screen Press STOP to stop the measurement S e t o u t l i n e P o i n t L i n e S e t o u t l i n e O f f s e t 0 0 0 0 m OBS C X130R book 70 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 79: ...is below the baseline Fill indicates that the point is above the baseline Lenght Distance along the baseline from the first point to the measured point Press NO to observe the target again 5 Sight the next target and press OBS to continue the measurement Press REC records measurement results CRecording method 20 RECORDING DATA RECORD MENU Set out line NO YES Tgt h 1 400m S e t o u t l i n e 0 006m...

Страница 80: ...DURE 1 In the second page of Meas mode screen press MENU then select Point Projection 2 Enter the instrument station data then define the baseline C 15 1 Defining Baseline step 2 to 13 3 Press OK to define the baseline Point projection is displayed Move to point projection measurement C 16 2 Point Projection 16 1 Defining Baseline Y direction X direction 1st Pt Length Offset Point to project Basel...

Страница 81: ...ta as a known point press FUNCTION and then press REC on the second page CRecording method 22 1 Registering Deleting Known Point Data 4 Press OK on the screen of step 3 The following items are calculated and displayed Length Distance along the baseline from the first point to the projected point X direction 16 2 Point Projection Stn Orientation Define baseline Point Projection Point projection P o...

Страница 82: ...ress XYZ to switch the screen display to coordinate values Press OFFSET to switch the screen display to distance values Press REC records the coordinate value as a known point data CRecording method 22 1 Registering Deleting Known Point Data Press N S O to move to setting out measurement of the projected point C 14 SETTING OUT MEASUREMENT 5 Press ESCAPE Continue the measurement repeat steps from 3...

Страница 83: ...hree ways explained below Finding it by entering the horizontal distance from the target point to the offset point When the offset point is positioned to the left or right of the target point make sure the angle formed by lines connecting the offset point to the target point and to the instrument station is almost 90 When the offset point is positioned in front of or behind the target point instal...

Страница 84: ...ered Coordinate Data 5 Select Offset Dist Input the following items 1 Horizontal distance from the target point to the offset point 2 Direction of the offset point Direction of offset point Press OBS to re observe the offset point 6 Press OK on the screen of step 5 to calculate and display the distance and angle of the target point On the left of the target point On the right of the target point C...

Страница 85: ...ind it from the included angle Install offset points for the target point on the right and left sides of and as close as possible to the target point and measure the distance to the offset points and the horizontal angle of the target point XPROCEDURE 1 Set the offset points close to the target point making sure the distance from the instrument station to the target point and the height of the off...

Страница 86: ...lay Offset 4 Enter the instrument station data C 12 1 Entering Instrument Station Data PROCEDURE Reading in Registered Coordinate Data 5 Select Offset Angle in Offset 6 Accurately sight the direction of the target point and press OK The distance and angle of the target point are displayed 7 After finishing measurement press YES to return to Offset Stn Orientation Offset Dist Offset Angle Offset 2D...

Страница 87: ...he optional equipment the 2 point target 2RT500 K When using this 2 point target be sure to set prism constant to 0 C 25 1 EDM Settings How to use 2 point target 2RT500 K Install the 2 point target with its tip at the target point Face the targets toward the instrument Measure the distance from the target point to the 2nd target Set the reflector type to sheet XPROCEDURE 1 Install two offset point...

Страница 88: ...esults are displayed Press YES The 2nd Target Observation Screen is displayed 6 Sight the 2nd target and press OBS The measurement results are displayed Press YES 7 Enter the distance from the 2nd target to the target point and press I The coordinates of the target point are displayed 8 Press YES Offset is restored When HVD is pressed display mode is switched from coordinates to S ZA HAR Stn Orien...

Страница 89: ... It is possible to change the last measured point to the next starting position Measurement result can be displayed as the gradient between two points XPROCEDURE 1 Sight the target of the starting position and press DIST in the first page of Meas mode to begin measurement The measured values are displayed Press STOP to stop measurement 18 1 Measuring the Distance between 2 or more Points X130R boo...

Страница 90: ...servation Slope distance horizontal distance and height difference between multiple points and the starting position can be measured this way When S is pressed the distance between two points S is displayed as the gradient between two points Press OBS to re observe the starting position Sight the starting position and press OBS When MOVE is pressed the last target measured becomes the new starting...

Страница 91: ... XPROCEDURE 1 Observe the starting position and target following steps 1 to 3 in 18 1 Measuring the Distance between 2 or more Points 2 After measuring the targets press MOVE Press YES Press NO to cancel measurement 18 2 Changing the Starting Point C Move 1st obs MLM C X130R book 83 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 92: ...NT 84 3 The last target measured is changed to the new starting position Perform missing line measurement following steps 2 to 3 in 18 1 Measuring the Distance between 2 or more Points X130R book 84 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 93: ...will occur Be sure to observe or recall points on an enclosed area in a clockwise or counterclockwise direction For example the area specified by entering or recalling point numbers 1 2 3 4 5 or 5 4 3 2 1 implies the same shape However if points are not entered in numerical order the surface area will not be calculated correctly XPROCEDURE Surface area calculation by observing points 1 In the seco...

Страница 94: ... an enclosed area are observed in a clockwise or counterclockwise direction For example the area specified by entering point numbers 1 2 3 4 5 or 5 4 3 2 1 implies the same shape After all known points necessary to calculate the surface area have been observed CALC is displayed 5 Press CALC to display the calculated area 6 Press OK to quit area calculation and return to Meas Mode C M E A S R E A D...

Страница 95: ...rent JOB or in the Coordinate Search JOB 3 Select the first point in the list and press I The coordinates of the first point is set as Pt 001 4 Repeat steps 2 to 4 until all points have been read in Points on an enclosed area are read in a clockwise or counterclockwise direction After all known points necessary to calculate the surface area have been observed CALC is displayed 5 Press CALC to disp...

Страница 96: ...19 SURFACE AREA CALCULATION 88 It is also possible to perform area measurement when AREA on the Meas mode screen CAllocating AREA 25 3 Allocating Key Functions X130R book 88 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 97: ... that can be recorded are the instrument station coordinates point number instrument height codes operator date time weather wind temperature air pressure and atmospheric correction factor If instrument station data is not stored for the current JOB the previously stored instrument data settings will be used XPROCEDURE 1 Press REC in the third page of Meas mode to display REC Current JOB name is d...

Страница 98: ...ore REC SET automatically increments the last input number by 1 Maximum point number size 14 alphanumeric Input range of instrument height 9999 999 to 9999 999 m Maximum code operator size 16 alphanumeric The Date and Time cannot be changed CChanging the Date and Time 25 2 Configuration Config Mode Setting Date and Time Weather selection Fine Cloudy Light rain Rain Snow Wind selection Calm Gentle ...

Страница 99: ...2 Select Angle data and sight the point to be recorded Angle measurement values are displayed in real time 3 Press REC and set the following items 1 Code 2 Target height 3 Point number 4 Check the input data then press OK 5 To continue measurement sight the next point then perform steps 3 and 4 above 20 2 Recording Angle Measurement Data REC Stn data Angle data Dist data Coord data Dist Coord data...

Страница 100: ... JOB XPROCEDURE 1 Press DIST in the first page of Meas mode to perform distance measurement C 11 2 Distance and Angle Measurement 2 Press REC in the third page of Meas mode REC is displayed Select Dist data to display the measurement results 3 Press REC and set the following items 1 Code 2 Target height 3 Point number 4 Check the input data then press OK 20 3 Recording Distance Measurement Data RE...

Страница 101: ...is deleted Once the data has been recorded REC is not displayed in order to prevent double recording Coordinate data can be stored in the current JOB XPROCEDURE 1 Perform coordinates measurement in the Meas mode screen C 12 COORDINATE MEASUREMENT 2 Press REC in the third page of Meas mode to display REC Select Coord data to display the measurement results 20 4 Recording Coordinate Data C C REC Stn...

Страница 102: ...urement data and coordinate data are recorded as the same point number Distance measurement data is recorded first then coordinate data is recorded XPROCEDURE 1 Press REC in the third page of Meas mode to display REC 2 Select Dist Coord data to display REC DIST C 3 Sight the point and press OBS to begin the measurement The measurement results are displayed 20 5 Recording Distance and Coordinate Da...

Страница 103: ... is selected XPROCEDURE 1 Press REC in the third page of Meas mode to display REC Select Note 2 Enter the note data 3 After inputting the note data press OK to return to REC Maximum note length 60 characters alphanumeric 20 6 Recording Notes N E Z AUTO OBS OFFSET 1 4 8 6 0 0 5 1 0 0 0 4 P t P N T 1 2 3 4 R E C D I S T C r e c 3 9 7 0 REC C N E Z 1 4 8 6 0 0 5 1 0 0 0 4 T g t h 0 0 0 0 m C d Note V...

Страница 104: ...o display REC Select View to display the list of recorded points 2 Select the point number to be displayed in detail and press I Details of the data is displayed This screen contains distance measurement data To display previous data item press PREV To display next data press NEXT KL P Use O G to move from page to page KL P Use O G to select individual point Press TOP to display first data Press L...

Страница 105: ...a are registered 3 Press ESCAPE to conclude detailed display and restore the list of points Press ESCAPE again to restore REC If more than two points with the same point name exist in the current JOB SET finds the newer data only X130R book 97 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 106: ...t data 22 1 Registering Deleting Known Point Data Coordinate Search JOB The registered coordinate data in the JOB selected here can be read into coordinate measurement resection measurement setting out measurement etc Scale correction SET calculates horizontal distance and coordinates of a point using measured slope distance If scale factor has been set scale correction is carried out during calcu...

Страница 107: ...with the desired JOB as the current JOB and press I The JOB is determined 5 Press S F Enter the scale factor for the current JOB 6 Press I JOB selection is restored 7 Align the cursor with Coord search JOB and press LIST Coord search JOB is displayed JOB JOB selection JOB name edit JOB deletion Comms output Comms setup J O B s e l e c t i o n J O B 1 L I S T C o o r d s e a r c h J O B J O B S F 1...

Страница 108: ...hose name to be changed C PROCEDURE JOB selection and scale factor setting 3 Select JOB name edit in JOB Input the new JOB name and press I JOB is restored Maximum size of JOB name 12 alphanumeric It is possible to clear the data within a designated JOB After the data has been cleared the JOB name returns to the name allocated when the SET was shipped A JOB that has not been output to an auxiliary...

Страница 109: ...umbers to the right represent the number of data items in each JOB 3 Align the cursor with the desired JOB and press I 4 Press YES The data within the JOB that is selected is deleted and JOB deletion is restored JOB JOB selection JOB name edit JOB deletion Comms output Comms setup X130R_21 FM 101 ページ 2003年10月14日 火曜日 午後8時51分 ...

Страница 110: ...ions Interfacing with the SOKKIA SDR Electronic Field Book and Command Explanations manuals When entering known point data from an external device SET does not check the repeated point number Communication setup can be performed in the known data as well Select Comms Setup in Known data G When inch is selected as the distance unit the value must be input in feet XPROCEDURE Using the key entry meth...

Страница 111: ... known point coordinate data from an external instrument 1 Connect SET and host computer 2 Select Known data in Memory Mode Current JOB name is displayed 3 Select Comms input to display Comms input Coordinate data starts to be entered from an external instrument and the number of received items is displayed on the screen When data reception is completed Known data is displayed Press ESCAPE to stop...

Страница 112: ...ress TOP to display top of point number list Press LAST to display end of point number list Press SRCH to search for point number Input the point number after Pt No The search may take time if many data are registered 4 Press DEL to delete the selected point number Press PREV to display previous data Press NEXT to display next data 5 Press ESCAPE to quit the point number list and return to Known d...

Страница 113: ... data within the current JOB XPROCEDURE 1 Select Known data in Memory Mode Current JOB name is displayed 2 Select View The point number list is displayed 3 Select the point number to be displayed and press I The coordinates of the selected point number are displayed 22 2 Reviewing Known Point Data Known data Job JOB1 Clear Comms setup Known data Job JOB1 Key in coord Deletion Comms input View X130...

Страница 114: ...a or observation data XPROCEDURE Inputting Codes 1 Select Code in Memory Mode 2 Select Key in code Enter the code and press I The code is registered and Code is restored Maximum code size 16 alphanumeric Maximum number of codes registered 40 XPROCEDURE Deleting codes 1 Select Code in Memory Mode 22 3 Registering Deleting Codes Memory JOB Known data Code Code Key in coord Deletion Clear list Code v...

Страница 115: ...PE to restore Code If you select Clear list in step 2 and then press YES all registered codes are deleted XPROCEDURE 1 Select Code in Memory Mode 2 Select Code view The registered code list is displayed 3 Press ESCAPE to restore Code 22 4 Reviewing Codes Code Key in coord Deletion Clear list Code view Code Key in coord Deletion Clear list Code view X130R_22 FM 107 ページ 2003年10月14日 火曜日 午後8時59分 ...

Страница 116: ...ication setup can be performed in the JOB menu as well Select Comms Setup in JOB G When inch is selected as the distance unit data is output in feet XPROCEDURE Outputting JOB data to host computer 1 Connect SET and host computer 2 Select JOB in Memory Mode 3 Select Comms output to display the JOB list 4 Select the JOB to be output and press I Out appears to the right of the JOB selected You can se...

Страница 117: ...nce measurement data and reduced data To stop output press ESCAPE XPROCEDURE Outputting JOB data to printer 1 Select JOB in Memory Mode 2 Select Comms output to display the JOB list 3 Select the JOB to be output and press I Out appears to the right of the JOB selected You can select as many JOBs as you want 4 Press OK 5 Connect SET and printer 6 Turn ON the printer SDR2X Obs data Reduced data JOB ...

Страница 118: ...t starts When the output is complete the JOB list is restored It is possible to continue output of the next JOB Select Obs data to output distance measurement data Select Reduced data to output distance measurement data and reduced data To stop output press ESCAPE X130R book 110 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 119: ...te data on the existing file and file data cannot be edited or deleted Sokkia supports CF cards up to 64MB The following diagram shows the key operations required to display Card mode Do not remove the compact flash card during data read write Doing so will cause data stored in the card or the SET to be lost Do not remove the battery or turn off the power during data read write Doing so will cause...

Страница 120: ...card comes in contact with water wipe it with a clean dry cloth until it is free of moisture before inserting it in the card slot G Do not remove the CF card during data read write XPROCEDURE Inserting the CF card 1 Slide in the button on the card cover 2 Insert the card until a click is heard 24 2 Inserting Removing the CF Card X130R_24 FM 112 ページ 2003年10月16日 木曜日 午後5時17分 ...

Страница 121: ... to the CF card Also if multiple JOBs are selected they can be saved to one file Data is saved in the CF card with extension name CRD Up to 72000 points can be stored in a 8MB CF card each file holds up to 10000 points However the number of points that can be saved is not fixed and depends on the number of files that are created 100points use about 8KB in the CF card 24 3 Storing JOB Data in the C...

Страница 122: ...en returns to the JOB list If ESCAPE is pressed while data is being recorded data recording is canceled Maximum size of JOB name 8 characters alphanumeric Characters used to make File name Alphabet capital letters only special characters If the date and time are not set the previous settings are used When a file is overwritten the overwritten file is deleted Card Save data Load known Pt File statu...

Страница 123: ...d in the file on the SET Card is restored To cancel reading press ESCAPE By selecting File Status file information can be displayed file names can be edited and files can be deleted When deleting all files together format the CF card C 24 6 Formatting the Card 24 4 Reading Known Point Data on the CF Card 24 5 Displaying and Editing Files in the CF Card Card Save data Load known Pt File status Form...

Страница 124: ...dit Details of the file are displayed 2 Press EDIT and enter a new file name Press I to enter the new file name The edited file name is displayed on the screen Card Save data Load known Pt File status Format ABCDE CRD FGH I CRD JKLMNOPQ CRD ZZZ CRD ABCDE CRD J a n 0 1 2003 1 7 0 2 ED I T DEL 5354b y t e Fo r ma t SDR33 2 3960 KB CF card memory used CF card memory size ABCDE CRD J a n 0 1 2003 1 7 ...

Страница 125: ...ard is formatted on the SET in the Card format menu By selecting Format the CF card can be formatted All files on the CF card are deleted including files with extension names other than CRD XROCEDURE 1 Select Format in the Card mode 2 Press YES to format the CF card When formatting is completed Card is restored 24 6 Formatting the Card Card Save data Load known Pt File status Format Con f i rm Ca ...

Страница 126: ...tted Read only file is on CF card Card error An error has occurred in loading or saving data on CF card Card full There is no room to enter data on CF card Card not found CF card is removed during card menu Insert card CF card is not inserted Invalid card Incorrect card is inserted No file There is no file loading known point data and displaying data Over files Files cannot be added because they e...

Страница 127: ...ed values of the temperature and air pressure Atmospheric correction factor can also be entered directly G Illum hold is displayed only when the guide light option is mounted Items set options and input range Factory setting 25 1 EDM Settings Mode Distance measurement Mode Fine r Fine AVG Setting 1 to 9 times Fine s Rapid s Tracking Reflector Prism Sheet None reflectorless PC Prism constant 99 to ...

Страница 128: ...correction factor in mountainous terrain as the difference in height will result in differences in atmospheric conditions between two points The SET is designed so that the correction factor is 0 ppm at an air pressure of 1013 hPa and a temperature of 15 C By inputting the temperature and air pressure values the atmospheric correction value is calculated and set into the memory Calculate the atmos...

Страница 129: ...ve prisms from Sokkia The following explains the Config Mode Press CNFG in any screen except during operation to start Config Mode zObservation Condition Select Obs condition in Config mode Items set and options Factory setting 25 2 Configuration Config Mode Dist mode Sdist Hdist Vdist Tilt crn Tilt angle compensation Yes H V Yes V No coll crn Collimation correction Yes No AP01 Constant 40mm Corre...

Страница 130: ...ed horizontal angle value to change Compensated horizontal angle Measured horizontal angle Tilt in angle tan Vertical angle When the telescope is directed close to the zenith or nadir angle tilt compensation is not applied to the horizontal angle Collimation correction The SET has a collimation correction function that automatically corrects horizontal angle errors caused by horizontal axis and le...

Страница 131: ...e Resume function is set to On and the power is switched off and then on again the screen appearing before the instrument was switched off is redisplayed Also all parameter settings are saved Memory backup period is about one week after which the Resume function is cancelled Power off 5min 10min 15min 30min No Reticle lev 0 to 5 level 3 Contrast 0 to 15 level 10 Resume On Off EDM ALC Hold Free Gui...

Страница 132: ...kes some time for the amount of light received to be adjusted and the measurement value displayed Set to Hold when the light beam used for measurement is stable but is frequently obstructed by obstacles such as people cars or tree branches etc The EDM ALC setting will automatically be switched to Free when the distance measurement mode is set to Tracking target is moved during distance measurement...

Страница 133: ...Even if inch is selected in this setting all the data including the result of area calculation are output in feet and all the distance values must be input in feet In addition when the inch display exceeds the range it is displayed in feet zDate and Time Temp Temperature C F Press hPa mmHg inchHg Angle degree gon mil Dist meter feet inch Date and Time Date Time Jan 01 2003 12 34 56 X130R_25 FM 125...

Страница 134: ...r User 1 and User 2 as necessary G When softkey allocations are recorded and registered the previously recorded key settings are cleared When a softkey array is recalled the key array is changed to the key array that has been recalled clearing the previous key array Be sure to remember this zThe following are the softkey allocations when the SET was shipped Page 1 DIST M SHV 0SET COORD Page 2 MENU...

Страница 135: ...Display final measurement data D_OUT Output measurement results to an external instrument AREA Surface area measurement F M Switch between meters feet HT Set the instrument station height and target height S O LINE Setting out line measurement P PROJ Point projection measurement No functions set zSoftkey Allocation Examples It is possible to allocate the same key to each page example 1 The same fu...

Страница 136: ...tion using O G Set the softkey function and its location by pressing L K The set softkey stops flashing and the cursor flashes on the next softkey 4 Repeat steps 2 to 3 only as many times as necessary 5 Press OK to record the allocations and restore Key function The functions with their new allocations are displayed in Meas mode XPROCEDURE Registering an allocation 1 Allocate functions to the soft...

Страница 137: ...Mode 2 Select Recall Select the key array for either User 1 User 2 or Default setting when the SET was shipped and press I Key function is restored This displays the functions in the recalled array in Meas mode Set password can be changed No password was set when the SET was shipped XPROCEDURE Changing password 1 Select Change Password in Config mode 2 Input old password and press I 25 4 Changing ...

Страница 138: ...tings when the SET was shipped EDM setting Config mode settings including softkey arrays CAbout initial settings when the SET was shipped 25 1 EDM Settings 25 3 Allocating Key Functions Initialize the data The following data is initialized Data within all jobs Known point data within memory Code data within memory XPROCEDURE Restoring set items to initial settings and turning power on 1 Turn the p...

Страница 139: ...e data and turning the power on 1 Turn the power off 2 While pressing F1 F3 and BACK SPACE press ON 3 The SET is turned on Clearing memory appears on the screen and all items are restored to their initial settings X130R book 131 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 140: ... target for distance measurement Calculation error Coordinates identical to the known point coordinates observed during resection exist Set another known point so that the known point coordinates do not coincide Checksum error A sending repetition error has occured between the SET and external equipment Send receive the data again Clock error Clock error occurs when the voltage of the lithium batt...

Страница 141: ...surement the observation of the target was not completed normally Sight the target accurately and press MLM to perform the measurement again Need offset pt Observation of the offset point during offset measurement was not completed normally Sight the offset point accurately and press OBS to perform the measurement again Need prism obs During REM measurement the observation of the target was not co...

Страница 142: ...from the target The instrument station coordinates calculated during resection are too high Perform the observation again During setting out line measurement scale factor has been less than 0 100000 or exceeded 9 999999 Print or send first JOB data output transmission to the host computer or output to the printer is not completed before JOB is cleared Either transmit the JOB to be cleared to the h...

Страница 143: ...e poor and due to the insufficient amount of reflective light measuring could not be carried out within the time specified Resight the target When using reflective prisms effectiveness will be improved by increasing the number of prisms used Too short Input password has fewer than 3 characters Password must have 3 or more characters and 8 or fewer characters If the printer cable is attached during...

Страница 144: ...or when it may have been damaged by a strong shock The bubble tube is made of glass so it is sensitive to temperature changes or to shock Check and adjust it as outlined below XPROCEDURE Checking and adjusting 1 Level the instrument and check the position of the bubble of the plate level C 7 2 Levelling steps 3 to 5 2 Turn the upper part through 180 and check the bubble position If the bubble is s...

Страница 145: ...for any position of the upper part If the bubble does not move to the center even when the adjustment has been repeated ask your Sokkia agent to adjust it XPROCEDURE Checking and adjusting 1 Perform the plate level inspection and adjustment or carefully use the plate level to level the instrument C 7 2 Levelling steps 1 to 2 2 Check the position of the bubble of the circular level If the bubble is...

Страница 146: ...e adjusting screws Also do not over tighten the adjusting screws as this may damage the circular level If the tilt angle shown on the display shifts from tilt angle 0 zero point the instrument is not correctly levelled This will adversely affect angle measurement Perform the following procedure to cancel the tilt zero point error XPROCEDURE Check 1 Carefully level the instrument If necessary repea...

Страница 147: ...the automatically compensated angles X1 and Y1 5 Rotate the top of the instrument through 180 Loosen the horizontal clamp and turn the instrument 180 while referring to the displayed horizontal angle then retighten the clamp 6 Wait a few seconds for the display to stabilize then read the automatically compensated angles X2 and Y2 7 In this state calculate the following offset values tilt zero poin...

Страница 148: ... 10 Wait a few seconds for the display to stabilize then store the automatically compensated angles X1 and Y1 Press YES to store tilt angles X1 and Y1 The new correction constant is displayed 11 Confirm that the values are in the adjustment range If both correction constant are within the range 400 30 select YES to renew the correction angle Instr const is restored Continue to step 12 If the value...

Страница 149: ...gles X4 and Y4 16 In this state the following offset values tilt zero point error are calculated Xoffset X3 X4 2 Yoffset Y3 Y4 2 When both offset values fall within the range 20 adjustment is completed Press ESCAPE to return to Instr const If one of the offset values Xoffset Yoffset exceeds 20 repeat the check and adjustment procedures from the beginning If the difference continues to exceed 20 af...

Страница 150: ...splay Collimation Select Instr const in the Config mode screen and select Collimation 2 Sight the reference point in Face 1 Sight the reference point in Face 1 and press OK 3 Sight the reference point in Face 2 Rotate the instrument 180 Sight the same point in Face 2 and press OK 4 Set the constant Press YES to set the constant Press NO to discard the data and return to Collimation 27 4 Collimatio...

Страница 151: ...the target moves parallel to the vertical line adjustment is unnecessary If its movement deviates from the vertical line have your Sokkia service representative adjust it XPROCEDURE Check 2 Vertical and horizontal reticle line positions G Perform the check procedure under slightly hazy and weakly scintillating conditions 1 Install a target at a point about 100m in the horizontal direction from the...

Страница 152: ... and read out the horizontal angle A2 and the vertical angle B2 Example Horizontal angle A2 198 34 20 Vertical angle B2 269 30 00 5 Do the calculations A2 A1 and B2 B1 If A2 A1 is within 180 20 and B2 B1 is within 360 40 adjust ment is unnecessary Example A2 A1 Horizontal angle 198 34 20 18 34 00 180 00 20 B2 B1 Vertical angle 269 30 00 90 30 20 360 00 20 If the difference is large even after repe...

Страница 153: ...d in the optical plummet adjust as follows XPROCEDURE Adjustment 3 Correct half the deviation with the levelling foot screw 4 Firmly hold down the top portion of the instrument and remove the optical plummet knob cover then remove the optical plummet reticle cover on the inside Replace the optical plummet knob cover Use the 4 adjusting screws of the optical plummet to adjust the remaining half of ...

Страница 154: ...hten the left right screw by the same amount 7 Check the adjustment by rotating the upper part of the instrument The surveying point should remain centered in the reticle If necessary repeat the adjustment 8 Remove the optical plummet knob cover and install the optical plummet reticle cover on the inside Replace the optical plummet knob cover G Do not over tighten the 4 adjusting screws as this ma...

Страница 155: ...edures Set up so that the instrument height and the target height are identical If a flat place is not available use an automatic level to make sure the heights are identical XPROCEDURE Check 1 Find an area of flat ground where two points 100m apart can be selected Set up the Instrument at point A and the reflective prism at point B Establish a point C half way between points A and B 2 Precisely m...

Страница 156: ...for the red and green guide lights is off centered from the reticle lines use the following procedures to make adjustments G The guide light is an optional function Set Illum Hold to Guide in Config mode Use the setting page to select check and adjust the guide light C 25 1 EDM Settings and 31 OPTIONAL ACCESSORIES XPROCEDURE Checks 1 Install a prism at a point about 20 meters in the horizontal dir...

Страница 157: ...the horizontal angle of the position that changes only to green from both colors red and green of the guide light colors that are reflected in the prism 8 Move the top of the instrument slightly while looking through the telescope measure the horizontal angle of the position that changes only to red from both colors red and green of the guide light colors that are reflected in the prism 9 Calculat...

Страница 158: ...en of the colors of the guide lights that are reflected in the prism The angle difference for procedures 7 and 8 is 1 30 with this the dividing line for the green and the red shifts to the right side the green side The illustration depicts how the left and right colors of the guide light are reflected in a prism and seen when viewed through the telescope When the angle difference is more than 1 pr...

Страница 159: ...t screw clockwise When only the green is visible or if the dividing line shifts onto the green side turn the guide light adjustment screw counterclockwise 11 Carry out a check of procedures 7 to 9 once again When the measurement value difference for the horizontal angle is more than 1 then repeat the adjustments for procedure 10 When the measurement value difference for the horizontal angle is les...

Страница 160: ...ry The EDC14 has a breaker switch Normally the red mark appears on the breaker If it cannot be seen set the breaker so it is visible When using a car battery make sure that the polarity is correct Standard equipment Others are optional accessories CDC14 100V AC CDC14D 220VACto240VAC 15 hours Battery BDC35A Ni MH BDC40A Ni Cd Charger CDC41 11 to 16 V DC For cigarette lighter External battery adapte...

Страница 161: ...en using a reflecting prism equipped with a target for distance and angle measurements be sure to direct the reflective prism correctly and sight the center of the prism target accurately Each reflective prism 1 has its own prism constant value When changing prisms be sure to change the prism constant correction value To use the triple prism assembly AP31 or AP32 as a single prism for short distan...

Страница 162: ...ustment methods of optical plummet C 27 6 Optical Plummet The height of the AP41 instrument height adaptor can be adjusted using two fixing screws Make sure that the instrument height 236 mm is displayed in the instrument height adjustment window Loosen the screws and rotate it counterclockwise Move the part up or down until the desired instrument height is displayed in the adjustment window then ...

Страница 163: ...er CDC39 CDC40 CDC48 1 4 Tubular compass CP7 1 5 Lens cap 1 6 Lens hood 1 7 Vinyl cover 1 8 Plumb bob 1 9 Tool pouch 1 10 Screwdriver 1 11 Lens brush 1 12 Adjusting pin 2 13 Cleaning cloth 1 14 OPERATOR S MANUAL 1 15 Carrying straps 1 16 Laser caution sign board Class3R only SET1130R3 2130R3 3130R3 4130R3 1 17 Carrying case SC141A 1 X130R_30 FM 155 ページ 2004年1月8日 木曜日 午前11時0分 ...

Страница 164: ...ot To use loosen the clamping screw to free the compass needle Turn the instrument in the face 1 position until the compass needle bisects the index lines The telescope will be nearly aligned with magnetic north After use tighten the clamp and remove the compass from the slot Place it in the specified position in the carrying case G Magnetism and metal will influence the tubular compass making it ...

Страница 165: ...30 STANDARD EQUIPMENT zHandle The carrying handle can be removed from the instrument To remove it unscrew the handle securing screws Handle Handle securing screws X130R book 157 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 166: ...ed infrared LED Power source R03 AAA 2 3V DC Operating range within 2m operating range may vary with different operating conditions Keyboard 37 keys Operating temperature 20 to 50 C Dust and water resistance IP44 IEC60529 1989 Size 162 W 63 D 19 H mm Weight about 120g with battery cells Changing battery cells G Be sure to replace all battery cells at the same time Either all alkaline or all mangan...

Страница 167: ...ery compartment Press down on the areas indicated by the arrows in the illustration below to close the cover zGuide light GDL2 Setting out measurements etc can be carried out effectively using the Guide light The Guide light is composed of a light that is divided into a red and green C Guide light status 4 1 Parts of the Instrument guide light ON OFF 5 1 Basic Key Operation Battery Cover Push down...

Страница 168: ...Size 162 W x 63 D x 19 H mm Weight about 120 g with battery cells zSideplate with card slot SCRC3 It has CF card slot C 24 CARD MODE zDiagonal eyepiece DE25 The diagonal eyepiece is convenient for observations near the nadir and in narrow spaces Magnification 30X After removing the handle from the SET loosen the attachment screw to remove the telescope eyepiece Then screw the diagonal lens into pl...

Страница 169: ... Magnification 40X Field of view 1 20 zInterface cable Connect between the SET and the host computer for data output Computer Cable Notes PC9800 Series DOC25 Length 2m Pin Numbers and signal levels RS 232C compatible D sub connector 25 pins female IBM PC AT or compatible DOC26 Length 2m Pin Numbers and signal levels RS 232C compatible DOC 27 D sub connector DOC26 25 pins female DOC27 9 pins female...

Страница 170: ...0 5 0 0001gon 0 002mil SET3130R 3130R3 4130R 4130R3 1 0 0002gon 0 005mil 5 0 001gon 0 020mil selectable Accuracy Standard deviation of mean of measurement taken in positions I and II ISO 12857 2 1997 SET1130R 1130R3 1 0 0003gon 0 005mil SET2130R 2310R3 2 0 0006gon 0 010mil SET3130R 3130R3 3 0 001gon 0 015mil SET4130R 4130R3 5 0 0015gon 0 025mil Measuring time Less than 0 5 sec Automatic compensato...

Страница 171: ...to 500m 1 640ft Reflective sheet RS50N K 1 3 to 300m 980ft Reflective sheet RS10N K 1 3 to 100m 320ft Compact prism CP01 1 3 to 800m 2 620ft Standard prism AP01 X 1 1 3 to 4 000m 13 120ft 1 3 to 5 000m 16 400ft 2 Standard prism AP01 X 3 to 5 000m 16 400ft to 6 000m 19 680ft 2 Mini pole prism OR1PA 1 3 to 500m 1 640ft Reflectorless White 3 SET1130R 2130R 3130R 4130R 0 3 to 150m 490ft SET1130R3 2130...

Страница 172: ...3 3130R3 4130R3 Fine measurement 3 2 ppm X D mm 0 3 to 200m 5 10 ppm X D mm over 200 to 350m Rapid measurement single 6 2 ppm X D mm 0 3 to 200m 8 10 ppm X D mm over 200 to 350m Reflectorless Gray 4 SET1130R 2130R 3130R 4130R Fine measurement 3 2 ppm X D mm 0 3 to 45m 5 5 ppm X D mm over 45 to 80m Rapid measurement single 6 2 ppm X D mm 0 3 to 45m 8 5 ppm X D mm over 45 to 80m SET1130R3 2130R3 313...

Страница 173: ...s when using Kodak Gray Card White side reflection factor 90 and brightness level is less than 30000 lx a little cloudy 4 Figures when using Kodak Gray Card Gray side reflection factor 18 and brightness level is less than 30000 lx a little cloudy 3 4 When performing reflectorless measurement the possible measurement range and precision will change depending on the target reflection factor weather ...

Страница 174: ...late level SET1130R 1130R3 2130R 2130R3 20 2 mm SET3130R 3130R3 4130R 4130R3 30 2 mm Circular level 10 2 mm Optical plummet Magnification SET1130R 1130R3 5 5X SET2130R 2130R3 3130R 3130R3 4130R 4130R3 3X Image Erect Minimum focus 0 3 m 0 98ft Operating temperature 20 to 50 C 4 to 122 F Storage temperature range 30 to 70 C 22 to 158 F Dust and water resistance IP64 IEC 60529 1989 Horizontal and ver...

Страница 175: ...ommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notic...

Страница 176: ...33 REGULATIONS 168 CE Conformity Declaration X130R_33 FM 168 ページ 2004年1月13日 火曜日 午後4時49分 ...

Страница 177: ...169 33 REGULATIONS X130R_33 FM 169 ページ 2004年1月8日 木曜日 午前11時5分 ...

Страница 178: ... method to Yes 2 Go to the Meas mode screen The vertical angle V1 is displayed under Take F1 3 Carefully level the instrument 4 Accurately sight a clear target with a distance of about 30m in the horizontal direction with the telescope in face left Press OK The vertical angle V2 is displayed under Take F2 5 Turn the upper part through 180 and clamp it Then set the telescope in the face right posit...

Страница 179: ...extremely precise instruments be used to monitor the air temperature and pressure Finding the average temperature and pressure between two points in different atmospheric conditions To precisely determine the atmospheric correction factor the average temperature and air pressure along the measurement beam route must be taken Determine the temperature and pressure as follows Flat terrain Use the te...

Страница 180: ...over a particularly long distance When taking humidity into consideration enter the atmospheric correction factor calculated using the following formula e water vapor pressure can be calculated using the following formula t Air temperature C p Pressure hPa e Water vapor pressure hPa h Relative humidity ew Saturated water vapor pressure 282 59 0 2942 p 1 0 003661 t 0 0416 e 1 0 003661 t Atmospheric...

Страница 181: ...X130R book 1 ページ 2003年10月8日 水曜日 午後12時53分 ...

Страница 182: ...2nd ed 04 0409 Printed in Japan 2003 SOKKIA CO LTD X130R_C3C4 fm 2 ページ 2004年9月21日 火曜日 午前10時49分 ...

Отзывы: