
7. SETTING UP THE INSTRUMENT
26
7. Center the SET over the
Surveying point
Loosen the centering screw
slightly.
Looking through the optical
plummet eyepiece, slide the
instrument over the tripod head
until the surveying point is exactly
centered in the reticle.
Retighten the centering screw
securely.
8. Check again to make sure the
bubble in the plate level is
centered
If not, repeat the procedure starting
from step 3.
X
PROCEDURE Levelling on the screen
1. Press
{ON}
to power on
2. Press
{
}
to display the circular
level on the screen.
“
z
” indicates bubble in circular
level. The range of the inside circle
is ±3' and the range of the outside
circle is ±6'.
Tilt angle values X and Y are also
displayed on the screen.
3. Center “
z
” in the circular level
C
"7.2 Levelling" steps 1 to 2
X130R_07.FM 26 ページ 2003年10月14日 火曜日 午後8時42分
Содержание 130R Series
Страница 8: ...vi X130R book vi ページ 2003年10月8日 水曜日 午後12時53分 ...
Страница 176: ...33 REGULATIONS 168 CE Conformity Declaration X130R_33 FM 168 ページ 2004年1月13日 火曜日 午後4時49分 ...
Страница 177: ...169 33 REGULATIONS X130R_33 FM 169 ページ 2004年1月8日 木曜日 午前11時5分 ...
Страница 181: ...X130R book 1 ページ 2003年10月8日 水曜日 午後12時53分 ...
Страница 182: ...2nd ed 04 0409 Printed in Japan 2003 SOKKIA CO LTD X130R_C3C4 fm 2 ページ 2004年9月21日 火曜日 午前10時49分 ...