2.ELECTRICAL COMPONENTS AND MEASUREMENTS
2.1 ON / OFF SWITCH
It can’t be measured from the electronical card.
C
T
DOOR SWITCH
CN2.9 -
CN2.2 0 Ω
KN2.8 -
KN2.10 0 Ω
Door is close
2.2 DOOR LOCK
It is a mechanical lock/release system that is closing the door, supplying the connection of electrical parts in
the machine and cutting off the connection.
From the electronical card:
C
T
DOOR SWITCH
CN2.9 -
CN2.2 0 Ω
KN2.8 -
KN2.10 0 Ω
Door is close
2.3 CIRCULATION PUMP
Single direction, single phase, asynchronus and two pole. It turns opposite clock direction. It is assambled
to the basement with rubber hangers.
From the electronical card:
You can only measure the primary winding value from the electronical card. Resistance value of the
primary winding must be;