Above sketch shows the connectors of the fan motor on the electronical card.
From the comonent:
2.16 RINSE AID SENSOR
From the electronical card:
C
T
RINSE AID SENSOR
CN 5.3 - CN 5.2
0
Ω NO RINSE AID
KN 50.8 - KN 50.9
0
Ω NO RINSE AID
RINSE AID OFF
∞Ω THERE IS RINSE AID
∞Ω THERE IS RINSE AID
RINSE AID ON
2.15 AUTO DOOR
Voltage: 110-230V,
Frequency: 50-60 HZ
Power : 5,5W ± 1W
The automatic door opening mechanism (ADOM) will be activated when the program is complete. Door
will open for 10cm when drying and rinsing is complete and the steam in the machine will be released for
better drying performance.
12
Turbo fan resistance value: 265 ± %10 Ω (The resistance of the torbo fan is measured with the resistor switch).