SOFTLINK Sigfox WS868-PLE-I Скачать руководство пользователя страница 25

discarded devices cannot be disposed as household waste. Equipment must be disposed of in the waste collection
yards, which dispose electronic waste. Information about the nearest collection yard can be provided by the relevant
local (municipal) authority.

4.6

WS868-PLE-I module installation

WS868-PLE-I radio modules are enclosed in plastic casings with IP20 degree of protection. The case consists of
two parts:

- back cover with printed circuit board (

base”)

- front lid with production tag

Both parts are screwed together and there is no reason to dismantle the casing during normal operation. View of
assembled module and view of module printed circuit board are displayed in the figure

17

View of WS868-PLE-I

module mounted to gas-meter is displayed in the figure

1

.

Figure 17: Detailed view of WS868-PLE-I module

The module is delivered fully assembled and activated in the Sigfox network. When mounting the device follow
these instructions:

1. If the battery was already switched on in preliminary phase of installation, the module was already pre-

configured and there is a possibility to perform setting of initial counter value by optical converter, it is not
necessary to open the casing before installation. In this case perform the module setting and installation this
way:

insert the module into the slot under gas-meter counter. L-shaped sealing protrusion should be oriented
to the right and must fit in the protrusion on the right side of the counter. Short plastic protrusion on
the upper left side of the module should be locked inside the gas-meter lock;

connect module sealing protrusion with matching protrusion on the gas-meter by sealing screw or sealing
wire (or other prescribed way) and seal the connection by antifraud seal;

check setting of broadcasting period and set initial counter value by using of optical converter as described
in paragraph

3.6

.

2. if the battery was not switched on yet, proceed in module setting and installation this way:

unscrew a screw on the module back cover and remove front lid;

switch-on battery by putting of shortening connector onto shortening pins. The pins are placed on the
PCB beside the battery lead (in the figure

17

marked by red rectangle);

connect the cable of USB-CMOS converter to the module configuration connector (in the figure

17

marked

by green rectangle) and perform setting of module as described in section

3

Module configuration”. Al-

ternatively, the configuration can be performed after mounting to gas-meter by using of optical converter
(see paragraph

3.6

).

save the configuration;

place front lid to the module base (the locks on the lid should be fastened in the base) and affix it by
screw. The module should be assembled before mounting to gas-meter;

insert the assembled module into the slot under gas-meter counter. L-shaped sealing protrusion should
be oriented to the right and must fit in the protrusion on the right side of the counter. Short plastic
protrusion on the upper left side of the module should be locked inside the gas-meter lock;

connect module sealing protrusion with matching protrusion on the gas-meter by sealing screw or sealing
wire (or other prescribed way) and seal the connection by antifraud seal;

WS868-PLE-I

22

Содержание Sigfox WS868-PLE-I

Страница 1: ...WIRELESS COMMUNICATION SYSTEM Sigfox WS868 WS868 PLE I Revision 1 0 SOFTLINK s r o Tomkova 409 278 01 Kralupy nad Vltavou Czech Republic Phone 420 315707111 e mail sales softlink cz www softlink cz...

Страница 2: ...of WS868 PLE I module parameters by configuration cable 13 3 5 1 List of WS868 PLE I module configuration parameters and commands 13 3 5 2 Commands for saving of configuration parameters and reset 13...

Страница 3: ...erter 6 7 Displaying of the optical converter in the Windows Device Manager 7 8 Displaying of WACO OptoConf configuration window 7 9 List of variables in the working window of WACO OptoConf program 7...

Страница 4: ...network server to the application servers of authorized users through the unified data interface via public Internet 1 2 Module usage The WS868 PLE I module can be used for remote reading of Elster BK...

Страница 5: ...ynchronous Transmission parameters 8 data bits 1 stop bit none parity Signal level TTL CMOS Optical configuration interface Transmission speed 115 200 Baud Optical interface specification IrPHY 1 4 st...

Страница 6: ...e to computer Configuration can be performed by using of common USB port of the computer For the interconnection with a USB port of computer it is necessary to use a manufacturer s original configurat...

Страница 7: ...nal setting for serial line communication PuTTY software runs after clicking on the downloaded file putty exe There will open a window of the terminal communication see Figure 4 For switching the prog...

Страница 8: ...ers HELP enter question mark or and press ENTER key when entering characters distinguish strictly the capital and small letters according to the documentation or HELP Do not enter other characters tha...

Страница 9: ...ow 3 2 2 Connection of USB IRDA optical converter to computer Before starting of the WACO OptoConf program connect the USB IRDA converter to USB port of the computer When the converter is connected to...

Страница 10: ...ystem communication systems can be found on the producer s WEB site NEP Page By clicking to Read device button the textbfconfiguration table with all the relevant parameters of the module is displayed...

Страница 11: ...n between module and converter is reliable When working directly at the installation site always use a special holder that is designed for attaching of converter to the module Put the holder to the WS...

Страница 12: ...s either bad position of the module long distance wrong orientation dirty cover obstacle in the beam or the module s battery was switched off NOTE WACO OptoConf program contains specific data and sett...

Страница 13: ...ce see figure 13 left Figure 13 Displaying of the device without driver in Device Manager window By right clicking to USB Serial port open the context menu and choose Update driver software item Click...

Страница 14: ...d Boot Options appears choose Disable Driver Sig nature Enforcement option in this window after launching the system install the driver according the above mentioned instructions Deactivation of the e...

Страница 15: ...g to the above described procedure Deactivation of the enforcement of signed driver function of the Windows 10 operating system is functional only until the next restart of the system 3 4 3 Support of...

Страница 16: ...M enable mode setup on startup ppm set Xtal ppm s sec set sending time in seconds m sec set measure time in seconds d n n th uplink message has downlink capability 0 no downlink i index value set init...

Страница 17: ...broadcasting period The period is set in seconds and the module broadcasts its INFO messages spontaneously with this period Example of setting of broadcasting period to 1 hour 3600 seconds and corres...

Страница 18: ...utput value counter value multiplier i index d value setting of divisor output value counter value divisor Important note The first input with index 0 that registers revolving of gas meter pivotal whe...

Страница 19: ...initialization mode Mode setup Do not use Only for factory setting ppm enteering of XTAL correction constant Do not use Only for factory setting D number debug statement switch on Do not use Only for...

Страница 20: ...t based on suspension cause 2 means Watchdog reset reset by watchdog system 3 means Error reset incorrect instruction or inconsistent data 4 means Power reset caused by low power voltage The parameter...

Страница 21: ...nf program window View of configuration table is depicted in figure 16 Figure 16 The WS868 PLE I module configuration table In the upper section of the table there are read only type of parameters fac...

Страница 22: ...ontract that is valid for configured device The Measure periode parameter is used for setting of analog quantities temperature voltage measurement interval in seconds More detailed description of this...

Страница 23: ...7 Structure of module data messages The WS868 PLE I module is intended for reading of data from Elster gas meters of BK G series and broadcasting of measured data through the Sigfox RF network Maximu...

Страница 24: ...capacity reduces frequency of broadcasting 4 2 The condition of modules on delivery Modules are delivered in standard cardboard boxes The modules are commonly delivered in fully operating status with...

Страница 25: ...de of the module should be locked inside the gas meter lock connect module sealing protrusion with matching protrusion on the gas meter by sealing screw or sealing wire or other prescribed way and sea...

Страница 26: ...as meter counter status and seal number Fill in the prescribed service documentation If possible arrange making of all appropriate changes in the database of the remote reading system immediately 4 8...

Страница 27: ...y batteries used in the wacoSystem modules that have been carefully selected and properly tested In case of battery replacement by user the new battery parameters should meet same technical requiremen...

Страница 28: ...ce these elements for the spare ones with proven functionality check correctness of module settings and perform the check of module overall functionality as described in paragraph 4 9 replace the modu...

Страница 29: ...nfiguration options of WS868 PLE I RF modules designed for operation in Sigfox IoT network in868 MHz frequency band that are a part of the Softlink s wacoSystem product family More information about a...

Отзывы: