60
itnetworks.softing.com/XG
MAINTENANCE
With the exception of the RJ45 socket, neither the main device nor the Active Remote
have any user parts that can be serviced by the user.
RJ45 SOCKET
Since RJ45 sockets are subject to wear and potential damage from an improperly crimped connector,
it is possible to remove the socket and replace it with a new one.
To do this, remove the two small screws on the RJ45 socket.
Insert an RJ45 cable into the socket. It is important that the locking lug of the plug
engages in the socket. Now pull the socket with the cable out of the device.
To install a new socket, proceed in reverse order.
BATTERY
The NetXpert XG2 uses a lithium-ion battery. To charge the battery, connect the
charger to the charging socket on the side of the tester and connect the charger to
the power source. Make sure the battery was charged overnight or for at least 5
hours, before using NetXpert XG2 for the first time.
This increases the accuracy of the charge status display in the long term.
The battery of the NetXpert XG2 cannot be serviced by the operator. In the event you
need to remove the battery, loosen the screws on the back of the NetXpert XG2 and
disconnect the cables from the battery. Be sure to disconnect any cables that connect
the battery to the device.
Users that require longer battery life for their NetXpert XG2 may purchase optionally
a “
high energy
batter pack”
, which consists of two lithium-ion cells in addition to the
classic NetXpert XG2 battery.
Note:
The high-quality Li-ion battery is designed for the entire life of the tester. Li-ion
batteries are hazardous waste and must be disposed of in accordance with local
regulations.
CLEANING
Use a clean, damp cloth to clean the NetXpert XG2. Before cleaning, disconnect all
cables from the device. Otherwise it may damage the device and cause personal injury.
Do not use harsh or abrasive cleaners or solvents.
STORAGE
When not in use, store the NetXpert XG2 in the supplied protective case.
The NetXpert XG2 must not be exposed to high temperatures (over 80°C) or
moisture. See the temperature limits in the
Specifications
section.