Figure 32 - Test setup for passive qualification test on copper links
Figure 29 - Test screen with tested and untested cables - FO
•
When testing fiber cables, you can decide whether these two parameters are
included in the test by setting a check mark in the
Loss & Length
key. If they
are included in the test, they are displayed in a separate tab in the top bar.
•
Loss and length are purely informative parameters. If there is no BERT error, the test result is
always a pass. However, the color turns yellow to alert the user to potential faults in the cable, in
case of a too long cable or too high attenuation in the link.
•
Enter the microscope menu by pressing the
Microscope
button. Do not forget
to plug in the microscope prior to entering the mosaic screen.