C A B L E TES T
38
itnetworks.softing.com/XG
Figure 39 - Test setup for setting the reference - Cu
Set Reference Fiber
Figure 40 - Set Reference FO
If you only want to perform a BERT test of fiber cables, it is not necessary to set a
reference. If you want to test Loss & Length, you have to set a reference first. Follow the
instructions on the main unit, which are in the form of GIF's and explain the procedure.
Each time the test setup changes, it is necessary to set a new reference. When new SFPs
are detected or a new cable type is selected, the user is prompted to set a reference.