5 Troubleshooting
5.1 Common Problems and Solutions
This section reports solutions to some common problems that may arise
during general use.
5.1.1 USB Driver Problems
If you connected the Starter Kit board to the PC before installing the
CodeWarrior user interface and the SofTec Microsystems Additional
Components, the Starter Kit USB driver may not have been correctly
installed on your system. Unplugging and replugging the USB cable is of no
use, since Windows has marked the device as “disabled”. As a
consequence, CodeWarrior cannot communicate with the Starter Kit board.
To restore the USB driver (provided both CodeWarrior and SofTec
Microsystems Additional components have been installed), perform the
following steps under Windows XP:
1.
Make Sure the Starter Kit is powered on.
2.
Connect the Starter Kit to the PC (via USB).
3.
Open the Control Panel (
“Start > Settings > Control Panel”
).
4.
Open the
“System”
options.
5. Select
the
“Hardware”
tab.
6. Click
the
“Device Manager”
button.
7. The
“uDART In-Circuit Debugger”
device will be shown with an
exclamation mark next to it. Double click on this device.
8. In
the
“General”
tab, click the
“Reinstall Driver”
button. Follow the on-
screen instructions.