ESI 3~6K-S1
user manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
75
ID029
Leakage current consistency
error
ID030
Grid voltage consistency error
ID031
DCI consistency error
ID033
SPI communication error
(DC)
ID034
SPI communication error
(AC)
ID035
Chip error (DC)
ID036
Chip error (AC)
ID037
Auxiliary power error
ID038
Inverter soft startup fails
ID041
Relay detection failure
ID042
Low insulation impedance
Check the insulation resistance
between the photovoltaic array
and ground (ground), if there is a
short circuit, the fault should be
repaired in time. If not solved,
please contact SOFARSOLAR
technical support.
ID043
Ground fault
Check ac output PE wire for
grounding.
ID044
Error setting input mode
Check the PV input mode
(parallel/independent mode)
setting of the inverter. If not,
change the PV input mode