GB
24
24
DATA MANAGEMENT
Recalling stored values
1. Switch the blood pressure
monitor on by pushing ( ).
The average value (AVG) of the
last three datasets will be dis-
played. If less than three records
are stored, then it will display the
latest record first.
2. Push the key ( ) or ( ) to get to
the desired datasets. While scroll-
ing, the number of the displayed
dataset will be shown in the left
bottom corner of the display.
If you leave a dataset displayed, date and time
of the measurement will also be shown. They
will be put through automatically.
3. If you would like to recall the
datasets of another user, first
push the key (
) to switch the
device off if the blood pressure
monitor is still in the “recall me-
mory” mode.
Push the key ( ) to enter the
mode “select user”, push the key
( ) again to select between user
1 and user 2. Push the key (
)
to confirm and switch the device
off. Start again with Step 1.
The most current dataset (1) is shown first.
Each new measurement is stored at dataset
(1). All other datasets are moved back by one
(2 becomes 3, etc.) and the last dataset (60) is
removed from the list.
Deleting stored values
If a measurement is not performed
correctly, you can delete all measu-
rement results for the selected user
as follows.
1. Push and hold keys ( ) and ( )
simultaneously while the blood
pressure monitor is in the “recall
memory” mode. “dEL ALL” (delete
ALL) will flash and be displayed.
Push (
) to exit the “delete” mode without
deleting datasets.
2. Push ( ) to confirm deletion,
and “dEL done” will be displayed.
The blood pressure monitor then
switches off automatically..
Содержание SYSTO MONITOR 180
Страница 2: ...Deutsch 2 English 16 Fran ais 30 Italiano 44 Nederlands 58 Espa ol 72 Portugu s 86 100...
Страница 3: ...1 2 3cm 2 3 4 AAA Alkaline...
Страница 17: ......
Страница 31: ......
Страница 45: ......
Страница 59: ......
Страница 73: ......
Страница 87: ......
Страница 101: ......
Страница 102: ...ARAB 100 Soehnle 40 300 300 40 START STOPP APG AP 5 2009 10993 10 2010 10993 Soehnle 30 30...
Страница 103: ...ARAB 101 101 LCD 104 104 107 106 109 108 111 EEG 42 93 MDD 0123 SN BF EC REP...
Страница 105: ...ARAB 103 4 2004 1060 EN 14 MPBetriebV 200 50 EC 12 2008 EU 19 2012 0123 EEC 42 93...
Страница 106: ...ARAB 104 1 2 3 3 2 4 kPA mmHg 5 done LCD 60 1 2 2 1 3 20 5 1 2...
Страница 107: ...ARAB 105 104 7 5 1 104 0 133 1 106 1 1 2 2 LCD...
Страница 108: ...ARAB 106 ISH WHO 1999 110 180 HT 109 100 179 160 HT 99 90 159 140 HT 89 85 139 130 84 80 129 120 80 120 HT 25...
Страница 109: ...ARAB 107 1 2 2 3 4 3 1 2 1 AVG 2 3 2 1 1 1 1 3 2 60 1 dEL ALL 2 dEL done...
Страница 110: ...ARAB 108 1 E 2 E 3 E 11 E 10 E 20 E 21 E XX 01 02 EExx Out...
Страница 112: ...110...
Страница 114: ...Distributed by LEIFHEIT AG Leifheitstra e 1 56377 Nassau Germany www soehnle com 17763 A 2 2019...