19
The arrow sign points to the according limit of the
display panel “PIECES”:
Weight over upper target weight
Weight between upper and lower target
weight
Weight under lower target weight
The arrow signs will show up at 20 gram.
Cancelling of limit value
Select and delete with
.
■
Totalizing function
• Piece weight can be calculated as
defined under “counting”.
• Press and empty scale.
• Place further goods.
• Press again
and empty scale.
Arrow sign shows to
.
Display total
• Press . When scale is empty.
Delete total in memory
• Press and then
.
■
PLU (Product Look Up) saving
PLU is used for storing information of constant used
parts, so the data can be recalled time saving form
the memory. Behind the PLU no. are located data of
tare weight, description and quantity. Depending on
each design the scale is able to save up to 1000 PLU.
Saving of PLU with weight calculation
• Place quantity.
• Enter quantity over keypad.
• Press and then
.
• Enter PLU number.
• Press .
• Enter description of PLU
(display panel “PIECE WEIGHT”).
•
press.
PLU is programmed.
Saving of PLU with known piece weight
• Enter piece weight in gram over
keypad.
• Press and then
.
• Enter PLU number.
• Press .
• Enter description of PLU
(display panel “PIECE WEIGHT”).
• Press .