8
SUNSYS FJB
- Ref.: IOMSUNIFXX01-GB 00
8
3. INSTALLATION
3.4.
FIXING OF THE FIELD
JUNCTION BOX
Recommended screw diameter: M5
Dimensions for the drilling of the Field Junction Box fixing screws
Field Junction Box model
A (mm)
B (mm)
C (mm)
8 strings (4 fi xing screws)
540
540
12 strings (4 fi xing screws)
720
540
16 strings (6 fi xing screws)
540
540
270
24 strings (6 fi xing screws)
540
540
540
Tightening torque of the screws for the reassembling of the cover
(min/max): 3 Nm / 3,5 Nm
3.3-1
Fixing screws of the cover
3.4-1
Field Junction box fi xing screws
3.3.
ASSEMBLING AND DISASSEMBLING OF THE COVER
Unscrew the fixing screws of the cover using a slotted head screw driver 10 mm.
2 x 8 screws for the Field Junction Box 24 strings
1 x 8 and 1 x 6 screws for the Field Junction Box 16 strings
1 x 8 screws for the Field Junction Box 8 strings and 12 strings
A
B
C