7
SUNSYS FJB
- Ref.: IOMSUNIFXX01-GB 00
ENGLISH
3. INSTALLATION
3.1. ENVIRONMENTAL
REQUIREMENTS
The following points must be considered for installation:
• The Field Junction Box is designed for both indoor and outdoor use.
• The Field Junction Box is exclusively designed for vertical fitting.
• Ensure a good flatness of foothold of the box fixations.
• If the wall is not flat, we recommend to use rigid profiles to fix the SOCOMEC Field Junction Box and to use wedges.
• The supports on which the Field Junction Box is fitted must be of non inflammable material. There must be no inflammable material
in the vicinity. If the device is fitted indoors, it is advisable to install a smoke detector.
• Ensure protection against wind, moisture, snow load and the direct exposure to sun radiation. (Special accessories may be
proposed by Socomec).
3.2. TRANSPORT – INSTRUCTIONS FOR HANDLING
CAUTION!
• Do not overturn the Field Junction Box.
• The Field Junction Box can be transported only in horizontal position and in an appropriate manner.
• During transport and storage the Field Junction Box must remain in its original packaging.
WARNING!
• If visible signs of damages due to the transport are noticed on the delivered product, do not install it or put it
into service. Check that the quality, the material and the type of products received are as ordered.
• For insurance reasons, visible faults, such as external damage on the packaging and/or on the product, must
be notified to the sender within seven days.
CAUTION!
• The device is heavy. For transport at least two people are necessary.
• If the Field Junction Box box must be transported over long distances, use adequate lifting equipment and means
of transport.