Socket & See PDL 234Plus Скачать руководство пользователя страница 10

SS004V2

Ordering Information

Item

Supplier Code

Socket and See PDL234Plus Part P

Loop testing Kit tester

SOC/PDL234Plus

Socket and See fused test leads

SOC/ITLS400

Specification Continued

Overvoltage Category

CAT III 300 V

Over Voltage Protection

440V AC No damage complete

recovery

Operating Temperature

0ºC to 40ºC

Operating Humidity

80% @ 31ºC to 50% @ 40ºC

Safety Compliance

BS EN 61010-2-030:2010

Probes

GS38 Compliant

Dimensions

140mm x 80mm x 31mm

Weight

250g

Содержание PDL 234Plus

Страница 1: ...Instruction Manual Specification PDL 234Plus Part P Loop Testing Kit SS004V2 Sn...

Страница 2: ...been designed to be used with suitable PPE including insulated gloves if required Caution refer to the instruction manual Construction is double insulated Product should be recycled as electronic was...

Страница 3: ...nderstand LED indication Quick and convenient non trip loop impedance test Mains voltage indication Incoming mains polarity test Socket wiring tester Carrying case included Contains 13A plug to IEC co...

Страница 4: ...ts AC LED INDICATION 207 AMBER 207 253 GREEN 253 RED Fault loop result LED s Table of correct and common socket wiring faults Polarity test indications Socket wiring and Polarity status LED s Mains vo...

Страница 5: ...en DO NOT PROCEED Investigation and remedial action is required before any further tests can be carried out 3 1 2 Incoming Supply Polarity Test With all three LED s illuminated green place your thumb...

Страница 6: ...ug in and out to see if it is just tarnished socket contacts or checking where the socket is located If it is at the furthest point of the end circuit a higher reading may be expected 100 Less than 10...

Страница 7: ...le 7 Faulty N E miswire NC N L Warble 8 Faulty N NC E L Warble 9 Faulty N L E reverse NC L E Warble 10 Faulty E L N reverse L NC N Warble 11 Faulty E N NC L Warble 12 Faulty E N miswire E NC L Warble...

Страница 8: ...rasives or solvents There are no user serviceable parts Contact Socket and See for parts and technical assistance Socket and See Century Road High Carr Business Park Newcastle Staffordshire UK ST5 7UG...

Страница 9: ...uracy to 1 and displayed on 3 LED s 207 VAC LOW 207 253 VAC STANDARD 253 VAC HIGH Loop Test No trip mode 3 wire testing Phase Neutral Earth all connected Test current 15mA at 253V AC Range Accuracy 1...

Страница 10: ...See fused test leads SOC ITLS400 Specification Continued Overvoltage Category CAT III 300 V Over Voltage Protection 440V AC No damage complete recovery Operating Temperature 0 C to 40 C Operating Hum...