46
765042231 Rev.001
C3
0
240
s
1
1
compressor switch-on minimum duration
C4 0 240 min
5
5
duration of compressor switch-off during the
cabinet probe error (“Pr1” code) that occurs
during storage; see also parameter C5
C5 0 240 min
3
3
duration of compressor switch-on during the
cabinet probe error (“Pr1” code) that occurs
during post blast chilling storage; also see
parameter C4
C6 0 199.0
°C/°F
(1) 60.0
60.0
condenser temperature above which the
blocked overheated condenser alarm is
activated (“COH” code)
C7 0 199.0
°C/°F
(1) 65.0
65.0
condenser temperature above which the
blocked compressor alarm is activated
(“CSd” code)
C8 0 15 min
0
0
blocked compressor alarm delay (“CSd”
code) (5)
C9 0 240 min
8
8
duration of compressor switch-on during the
cabinet probe error (“Pr1” code) that occurs
during post deep freezing storage; also see
parameter C4
Par.
Min.
Max.
Unit
EVX803..02
SBU 15
EVX803..01
SBU 20/40
Defrosting (6)
d0 0 99
h
0
0
defrosting interval (7)
0 = defrosting will never be activated at
intervals