Loose electrical connections.
Blown Fuse.
Motor Seized.
Jammed auger.
Poor electrical connections.
Electrical short.
Controller failure.
Empty hopper.
Wet material.
Frozen or coarse material.
Spinner not turning.
Auger loose on shaft.
Vibrator not working.
Jammed auger, overload shut down.
Short in system.
Motor is not getting power.
Vehicle battery is extremely low,
or a poor connection exists.
Whenever service is necessary, your local SnowEx Dealer knows your Spreader best. Take your Spreader to your local dealer for
any maintenance or service needs on your unit. If this is not possible, the Troubleshooting Guide below may assist you in
identifying the problem.
Warning:
First read all warning instructions and safety messages before servicing your spreader.
Preliminary Checks
t
Be sure all electrical connections are tight and clean.
t
Be sure nothing is jammed in the hopper.
Motor doesn’t run.
Controller shut down.
Material not flowing
from hopper.
Audible alarm beeping and
display shows OL or OH.
Audible alarm beeping
display shows E1.
Audible alarm beeping
display shows EO.
Audible alarm beeping
display shows LB.
Check all connections.
Replace fuse.
Replace motor.
Carefully clear jammed material.
Clean or replace connectors.
Use dielectric grease.
Check electrical connections.
Check for bare wires.
Replace controller.
Fill hopper.
Replace with dry material.
Replace material.
Check drive assembly.
Tighten locking bolt on the side of the auger. There is a flat
machined on the driver shaft. Align the auger with this flat
and tighten the bolt.
Replace vibrator
Turn off for three seconds, then restart. If shut down
continues, turn off controller. Clear debris and lumps from
auger areas.
Turn off. Do not use until problem is corrected.
Turn off. Check all connections.
Turn off. Charge battery.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Содержание SP-9300
Страница 9: ...Trynex International 2009 L1218 MAX 9 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 10: ...L1218 Trynex International 2009 MAX 10 Auger Drive Assembly Parts Breakdown Model SP 9300...
Страница 12: ...L1218 Trynex International 2008 MAX 12 Spinner Drive Assembly Parts Breakdown Model SP 9300...
Страница 14: ...L1218 Trynex International 2009 MAX 14 Hopper Assembly Parts Breakdown Model SP 9300...
Страница 16: ...L1218 Trynex International 2009 MAX 16 Frame Assembly Parts Breakdown Model SP 9300...
Страница 36: ...Trynex International 2009 L1218 MAX 36 THIS PAGE INTENTIONALLY LEFT BLANK...