19
7. Troubleshooting
Problem
1. The pump unit
cannot be installed
2. Unable to
smoothly pump the
pump unit. Resistant
to pumping action.
3. Fuel leaks out of
the pump knob
while pumping.
4. Fuel leaks from
the seal gasket
resulting in reduced
pressure.
5. Fuel-air mixture is
not ejected from the
stove head, even
when the main
valve knob is
open.
Possible cause
Threaded part of pump unit
and/or fuel hose has been
damaged.
Seal gasket has not been
properly placed.
Pump shaft may be dirty.
May be worn, shaft may be
bent or damaged.
Bottom cap is not properly
attached.
Ball is worn or damaged.
Ball spring is worn or
damaged.
Pump unit is not firmly
tightened in the fuel bottle.
Seal gaskets are worn or
damaged.
Seal gaskets are dirty.
Flame control is fully
open.
Fuel bottle is not filled with
white gasoline.
Fuel bottle is not
pressurized due to lack of
pumping.
Fuel hose is clogged.
Remedy
Threaded part of pump unit and/or fuel hose
has been damaged.
Seal gasket has not been properly placed.
Remove dirt from the shaft and lightly apply
maintenance grease. A worn or damaged
shaft must be returned to place of purchase or
to Snow Peak for repair.
Attach the bottom cap properly; replace any
parts that have been worn or damaged.
Replace worn or damaged seal gaskets and
remove any foreign matter.
If the fuel leak persists, do not use the stove.
Open the flame control by turning it fully
counterclockwise .
Confirm that the white gasoline is not
exceeding the Fill Level line.
Pressurize the Fuel Bottle by placing thumb
over the hole in the center of the pump
knob and pumping approximately 50
times. In cold weather (i.e., below freezing)
gaskets may shrink or contract resulting in
reduced pressure. Under such circumstances,
pump an additional 20-30 times for optimal
pressurization.
Turn the main valve clockwise to close.
Remove the fuel hose. Turn the main valve
slightly counterclockwise to determine if
the fuel can be injected. If the fuel is not
injected from the pump unit, the pump unit has
been damaged and must be returned to the
place of purchase or to Snow Peak.
Connect the fuel hose to the pump unit. Open
the main valve slightly; if the fuel is not
injected from the other end of the fuel hose,
the fuel hose may be clogged. Replace the
fuel hose.
Содержание GigaPower WG STOVE
Страница 1: ...Instruction Manual...