Model: Snorkel SR9244 SR1054
Part Number: 159-0037-000
Snorkel International, LLC
2009 Roseport Road
Elwood, KS 66024
4343
4
SCR heater urea pressure line; short circuit to ground
4343
5
SCR heater relay urea pressure line; open load
4343
5
SCR heater relay urea pressure line; open load
4343
11
General pressure check error (SCR)
4345
3
SCR heater urea return line; short circuit to battery
4345
4
SCR heater urea return line; short circuit to ground
4345
5
SCR heater relay urea return line; open load
4345
5
SCR heater relay urea return line; open load
4345
11
Sensor backflow line pressure (SCR); plausibility error
4360
0
Physical range check high for urea catalyst upstream temperature
4360
1
Physical range low for urea catalyst upstream temperature
4361
3
Sensor error urea catalyst exhaust gas temperature upstream; signal range check
high
4361
4
Sensor error urea catalyst exhaust gas temperature upstream; signal range check
low
4365
0
Urea tank temperature too high
4366
3
SCR Tank heating valve; short circuit to battery
4366
4
SCR Tank heating valve; short circuit to ground
4366
5
SCR main relay (secondary side): open load
4366
5
SCR main relay; short circuit
4366
5
SCR main relay; short circuit
4366
5
SCR Tank heating valve; open load
4366
5
SCR Tank heating valve; open load
4366
12
SCR-heater relay urea tank powerstage output; over temperature
4374
13
Pressure stabilisation error dosing valve (SCR)
4375
3
Urea pump motor; short circuit to battery
4375
4
Urea pump motor; short circuit to ground
4375
5
Urea pump motor; open load
4376
3
SCR reversing valve; short circuit to battery
4376
4
SCR reversing valve; short circuit to ground
4376
4
SCR reversing valve; short circuit to ground
4376
5
SCR reversing valve; open load
4376
5
SCR reversing valve; open load
4376
12
SCR reversing valve; over temperature
4376
12
SCR reversing valve; over temperature
523009
9
Pressure Relief Valve (PRV) reached maximum allowed opening count
523009
10
Pressure relief valve (PRV) reached maximum allowed open time
523330
14
Immobilizer status; fuel blocked
523470
2
Pressure Relief Valve (PRV) forced to open
523470
2
Pressure Relief Valve (PRV) forced to open
523470
7
Maximum rail pressure in limp home mode exceeded (PRV)
523470
11
Pressure Relief Valve (PRV) error; Rail pressure out of tolerance range
523470
11
Rail pressure out of tolerance range
523470
12
Pressure Relief Valve (PRV) forced to open; system reaction initiated
523470
12
Pressure Relief Valve (PRV) forced to open; system reaction initiated
523470
14
Pressure Relief Valve (PRV) is open
523613
0
Rail pressure disrupted
523613
0
Rail pressure disrupted