9
Timeout Error (PCK2PCK) for CAN-Receive-Frame AT1IGCVol1 information; factors &
Sensorcalibration for NOX Sensor (SCR-system upstream cat; DPF- system
downstream cat)
523941
9
Timeout Error (BAM to packet) for CAN-Receive-Frame AT1OGCVol2 information;
factors & Sensorcalibration for NOX Sensor (SCR-system downstream cat; DPF-
system downstream cat)
523942
9
Timeout Error (BAM to BAM) for CAN-Receive-Frame AT1OGCVol2 information;
factors & Sensorcalibration for NOX Sensor (SCR-system downstream cat; DPF-
system downstream cat)
523943
9
Timeout Error (PCK2PCK) for CAN-Receive-Frame AT1OGCVol2 information; factors
& Sensorcalibration for NOX Sensor (SCR-system downstream cat; DPF- system
downstream cat)
411
4
Physical range check low for EGR differential pressure
108
3
Sensor error ambient air pressure; signal range check high
108
4
Sensor error ambient air pressure; signal range check low
97
3
Sensor error water in fuel; signal range check high
97
4
Sensor error water in fuel; signal range check low
94
3
Sensor error low fuel pressure; signal range check high
94
4
Sensor error low fuel pressure; signal range check low
94
1
Low fuel pressure; system reaction initiated
94
1
Low fuel pressure; system reaction initiated
174
0
High low fuel temperature; system reaction initiated
174
0
High Low fuel temperature; system reaction initiated
523619
2
Physical range check high for exhaust gas temperature upstream (SCR-CAT)
523916
2
Sensor HCI dosing valve (DV1) downstream pressure; plausibility error
523916
0
Physical range check high for HCI dosing valve (DV1) downstream pressure; shut off
regeneration
523916
1
Physical range check low for HCI dosing valve (DV1) downstream pressure; shut off
regeneration
523916
3
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check high
523916
4
Sensor error HCI dosing valve (DV1) downstream pressure; signal range check low
523917
2
Sensor DV1 & DV2 upstream pressure; plausibility error
523917
0
Physical range check high for DV1 & DV2 upstream pressure; shut off regeneration
523917
1
Physical range check low for DV1 & DV2 upstream pressure; shut off regeneration
523917
3
Sensor error DV1 & DV2 upstream pressure; signal range check high
523917
4
Sensor error DV1 & DV2 upstream pressure; signal range check low
523615
5
Metering unit (Fuel-System); open load
523615
12
Metering unit (Fuel-System); powerstage over temperature
523615
3
Metering unit (Fuel-System); short circuit to battery
523615
4
Metering unit (Fuel-System); short circuit to ground
523615
3
Metering unit (Fuel-System); short circuit to battery
523615
4
Metering unit (Fuel-System); short circuit to ground
100
3
Sensor error oil pressure; signal range check high
100
4
Sensor error oil pressure sensor; signal range check low
100
0
High oil pressure; system reaction initiated
100
0
High oil pressure; system reaction initiated
100
1
High oil pressure; system reaction initiated
100
1
High oil pressure; system reaction initiated