124
Model: Snorkel SR9244 SR1054
Part Number: 159-0037-000
Snorkel International, LLC
2009 Roseport Road
Elwood, KS 66024
Proper operation is guaranteed and damage is minimised thanks to the water tank having a level sensor. In
any case make sure that the liquid level is between minimum and maximum.
Attention! Frequent top-ups require the assistance service to intervene.
Typical characteristics of the coolant liquid:
•
Mix 50% in volume with water
•
Density at 20°C 1.131 kg/l
•
Boiling point 155°C
•
Freezing point -35°C
DRAIN THE WATER FROM THE FUEL PRE-FILTER
5.12.3
•
Continue with engine off;
•
Place a container under the pre-filter to collect the liquids;
•
Disconnect the power cord connections;
•
Unscrew the drain plug (6) found in the lower part of the pre-filter;
•
Drain the liquid until only "diesel" is present:
•
Close the cap again by turning it completely by hand;
•
Reconnect the electrical system cables;
•
Dispose of the drained liquids according to the relevant regulations in force
1.
Vent screw
2.
Fuel pump supply
3.
Fuel return from the FCU pilot block (Fuel Control Unit)
4.
Fuel delivery pump
5.
Electrical connection for the water level sensor
6.
Drain plug
7.
Filtering cartridge
8.
Fuel tank input
9.
Fuel tank return
Содержание SR1054
Страница 1: ...February 2019 Part Number 159 0037 000 MANUAL OPERATOR S and MAINTENANCE Replaces January 2019...
Страница 195: ......