Platform Work Lights
The optional platform work lights are located on
top the platform guardrail. For the lights to work,
the Battery switch must be ON and the following
switches, on the ground control box, must be set
as indicated:
Platform/Ground Selector . . . . . . PLATFORM
Emergency Stop . . . . . . . . . . . Pulled Out (ON)
Master Key Switch . . . . . . . . . . . . . . . . . . . ON
The toggle switch on the back of a light turns it on.
Incandescent lights draw three amperes (35
watts) each. Halogen lights draw four amperes
(50 watts) each.
If you work with the lights turned on and the
engine turned off, the battery can discharge to
the point it will not start the engine nor run the
Emergency Power hydraulic pump.
If you cannot leave the engine running while
the lights are on, start and run the engine at
least 15 minutes in each hour to keep the
battery charged.
❑
Tipover Hazard Light
This light will come on when the front axle should
be locked but is not. The axle unlocked alarm will
sound when this light is on. When this light
comes on you should immediately completely
lower the booms.
Drive the ATB to a slightly different position then
raise the booms again. If the alarm comes on,
take the machine out of service IMMEDIATELY
and refer the problem to a qualified service
technician. For more information about the axle
lock, see “Axle Unlocked Alarm” at the start of
this chapter.
page 2 - 8
ATB 42/50 – 0161987
2. Safety Devices
CAUTION
Содержание ATB 42
Страница 14: ...ATB 42 50 0161987 page 1 5 1 Safety PLATFORM LPG option only Tow option only Courtesy of Crane Market...
Страница 15: ...page 1 6 ATB 42 50 0161987 1 Safety PLATFORM CONTROL BOX Courtesy of Crane Market...
Страница 16: ...ATB 42 50 0161987 page 1 7 1 Safety Courtesy of Crane Market...
Страница 81: ...page 11 6 ATB 42 50 0161987 11 Options Courtesy of Crane Market...