SuperVisor LX
SECTION 3
FGAX3249400MANAA
100701
Version 1 Issue 2
3.2
Supervisor LX Mainframe Connections
POWER CONNECTIONS
Power Supply
There are two filtered IEC connectors with integral
fuse holders for the connection of mains power to
the unit. The fuse rating for each connector is
2.5 A (T).
The unit can accommodate two separate supplies
and the position of the connectors coincides with
the position of the power supply modules.
If only one PSU module is to be installed it should
be fitted in the position marked MAIN. The unit will
operate correctly when power is connected to
connector marked MAIN.
Fitting and powering-up a second power supply
module in the position marked SPARE will provide
continued operation if the MAIN power supply
module should fail.
When two power supply modules are fitted both
IEC connectors can be connected to the same or
different power sources.
Note that the power outlet(s) supplying power to
the unit should be close to the unit and easily
accessible
The power supply module(s) are Snell & Wilcox
generic type SHDPSUA15.
Caution!
The fan ventilation hole above the mains
inlet connector must not be obscured.
Fu
s
e
Fu
s
e
AC INPUT
100-240V~50/60 Hz
1.2A MAX
FUSE 2.5 A(T)