IQH1S IU Enclosure
SECTION 4
IQH1SOPS
23/11/06
www.snellwilcox.com
Version 1 Issue 4
4.27
Logging Fields
Field Name
Field Name
Description
Valid Field Values
Usage Description
SN
Serial Number
Serial Number
Format is standard S&W serial number
consisting of character ‘S’ followed by eight
digits, e.g. “S12345678”
VERSION
Hardware
Version
Version Number
Format: “<PCB name>/<mod strike>”, e.g.
“RCIF3U2Y/2”
BUILD_NUMBER
Build Number
Text
For K_OS-based units, this is typically a ten-digit
string, e.g. “0123456789”.
Future units may use a different format.
OS_VERSION
OS Version
OS Name & Version
Format: “<OS String> <Version String>”, e.g.
“KOS V115”
HARDWARE_VERSION
Hardware
Version
Version Number
Format: “<PCB name>/<mod strike>”, eg
“RCIF3U2Y/2”
MODULE_STATUS=
OK
1 EXTRA MODULE
n EXTRA MODULES
1 MODULE MISSING
n MODULES MISSING
1 WRONG TYPE
n WRONG TYPES
where 2 <= n <= 6
Status of module type/per slot configuration
matching or Modules mismatched / missing
SESSIONS
Control
Sessions
Number
0….n – No. of connected CONTROL sessions
LAST_MODIFIED
Last Modified
UTC Timestamp
The time a control was last modified on a unit.
Format: as per ISO 8601 for Co-ordinated
Universal Time (UTC), ie YYYY-MM-
DDTHH:MM:SSZ,
where the trailing ‘Z’ indicates UTC rather than
local time.
FAULT
Internal fault
status of unit
NONE
FAIL: <fault
description>
This field is used to report internal hardware or
software faults detected by a unit (as distinct
from external error conditions, e.g. loss of input).
RECON_STATE=
OK
Warn
Fail
0 RollNet reconnections in last 10 seconds
1 Rollnet reconnection in last 10 seconds
>1 RollNet reconnection in last 10 seconds
UPTIME
Uptime in
seconds
Number
DDD:HH:MM:SS
Uptime in specified format updated every
minute, NOTE: field value is zero buffered
001:08:10:00 (is 1 day, 8 hours, 10 minutes, 0
seconds)
RESTARTED_AT
Last Restarted
(UTC)
UTC Timestamp
UTC Time of last reboot, formatted as per
ISO8601 as above.
TEMP_1_NAME
Name of temp
sensor
TEXT
Function name such as Temperature In,
Temperature Out
Internal Temperature, PSU Temperature, etc.
These are set by the product and are not user
settable.
TEMP_1_STATE
Temperature
status
WARN: Low
WARN: High
OK
FAIL : Low
FAIL: High
WARN: Disabled
Temp below normal operating range, but not
critical
Temp above normal operating range, but not
critical
Temp is within operating range
Temp below normal operating range, Critical
Temp below normal operating range, Critical
Temperature detection has been manually
disabled
Each product must specify its own operating ranges
and safety thresholds, however suggestion is that
WARN thresholds exist 5 degrees C away from
defined product FAIL thresholds. e.g. : Product
Specification is 0-40 Degrees C, so WARN will be <=
5 and >=35.