BT-T080 Programming Manual
- 50 -
GS w n Set barcode width
[Function]
Set barcode width.
[Format]
ASCII GS
w
n
Hex
1D
77
n
Hecimal 29 119 n
[Value range]
2
≤
n
≤
6
[Notes]
Set the horizontal width of the barcode.
n specifies the barcode width in horizontal:
Module Width (mm) for Binary-level Barcode
n
Module Width (mm) for
Single-level Barcode (mm)
Thin basic module (mm)
Thick basic module (mm)
1 0.125
0.125
0.375
2 0.25
0.25
0.625
3 0.375
0.375
1.0
4 0.5
0.5
1.25
5 0.625
0.625
1.625
6 0.75
0.75
1.875
• Single-level barcode is as following:
UPC-A, UPC-E, JAN13 (EAN13) , JAN8 (EAN8) , CODE93, CODE128
• Binary-level Barcode is as following:
CODE39, ITF, CODABAR
[ Default ]
n = 2
[Relative]
GS k
GS p n Set the size of PDF417 barcode
[Function]
Set the parameters that used to define the size of PDF417 barcode.
[Format]
ASCII GS
p
nA nB nC nD nE nF
Hex
1D
70
nA nB nC nD nE nF
Decimal 29
112
nA nB nC nD nE nF
[Value range]
1
≤
nA
≤
10 , 1
≤
nB
≤
100, 3
≤
nC
≤
90, 1
≤
nD
≤
30, 1
≤
nE
≤
7, 2
≤
nF
≤
25
[Notes]
The meaning of n is defined as follows:
nA and nB is valid when nC and nD equals to zero.
Parameters
Meaning of parameters
nA
Aspect scale factor of height
nB
Aspect Scale factor of width
nC
Number of rows
nD
Number of columns
nE
Width of basic cells
nF
Height of basic cells