BT-T080 Programming Manual
- 6 -
[Relative] ESC
D
[Example]
0A
(set the print position to the beginning of the line)
1B 40
(initialize printer)
B 53
(enter standard mode)
33 33 33 33 33 33
1B 44 08 10 1C 00
(set the horizontal tab position)
09
(move the print position to the next tab)
33 33 33 33
09
(the same as above)
33 33 33 33
09
(the same as above)
33 33 33 33
0A
33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33
0A
(print)
Results:
ESC $ nL Nh Set absolute horizontal printing position
[Function]
Set absolute horizontal printing position.
[Format]
ASCII ESC $ nL nH
Hex
1B
24 nL nH
Decimal 27
36 nL nH
[Value range]
0
≤
nL
≤
255
0
≤
nH
≤
255
[Notes]
• The distance from the beginning of the line to the print position is [(nL + nH×256)×
horizontal or vertical motion unit].
• Settings outside the specified printable area are ignored.
• In standard mode, the horizontal motion unit (x) is used..
• In page mode, this command functions as follows, depending on the direction and
print starting position of the printable area:
When the starting position is set to the upper
①
left or lower right of the printable area
by
ESC T
, the horizontal motion unit (x) is used.
When the starting position is set to the upper right or lower left of the printable area
②
by
ESC T
, the vertical motion unit (y) is used.;
[Relative]
ESC \, GS $, GS \